6. To remove high voltage capacitor.
(1) Remove a screw @® which secure the
grounding ring terminal @ of diode and
capacitor holder @.
(2) Remove
a screws ® which secure the
capacitor holder @.
(3) Remove capacitor holder ® with capacitor
(4) Reverse the above steps for reassembly.
7. To remove magnetron.
(1) Remove a screw @ which secure the wind
guide.
(2) Remove the wind guide @.
(3) Remove two screws @) which secure the
duct.
(4) Remove the duct ®.
(5) Remove
foru nuts ©) which secure the
magnetron ©).
(6) Remove the magnetron.
(7) Remove two screws @ which the ther-
mostat (©).
(8) Remove the thermostat.
(9) Reverse the above steps sfor reassembly.