Replacing The Traction Belt; Fuse - Toro Z Master Z-320 OUT FRONT Z Operator's Manual

Traction unit
Table of Contents

Advertisement

Maintenance

Replacing the Traction Belt

Check traction drive belt for wear after every 50
hours of operation.
1.
Remove PTO belts; refer to Replacing Power
Take Off (PTO) Belts.
2.
Push spring loaded idler down and remove
traction belt from the engine, fixed idler and
hydro pump pulleys (Fig. 35). Remove belt over
clutch.
3.
Install new belt over clutch and around engine,
fixed idler and hydro pump pulleys (Fig. 35).
4.
Push spring loaded idler down and align below
traction belt. Release pressure on spring loaded
idler (Fig. 35).
5.
Install PTO belts; refer to Replacing Power Take
Off (PTO) Belts.
3
2
1
Figure 35
1. Traction belt
2. Engine pulley
3. Fixed idler pulley
34
4
5
m–3225
4. Hydro pump pulley
5. Spring loaded idler

Fuse

Service Interval/Specification
The electrical system is protected by fuses. It requires
no maintenance, however, if a fuse blows check
component/circuit for malfunction or short.
Fuse:
Main F1–30 amp, blade-type
Alternator F2–25 amp, blade-type
Safety Interlock and Clutch F3–15 amp,
blade-type
1.
Remove dash panel screws to gain access to fuse
holder (Fig. 36).
2.
To replace fuses pull out on the fuse to remove it
(Fig. 36).
3
2
1
Figure 36
1. Main-30 amp
2. Alternator-25 amp
4
m–3223
3. Safety interlock and
clutch-15 Amp
4. Screw

Advertisement

Table of Contents
loading

This manual is also suitable for:

74180