Interface Lines: Specifications - IBM 2420 7 Manufacturer’s Information Brochure

Magnetic tape unit
Table of Contents

Advertisement

Input Lines (From Tape Control)
dc Voltage
Rise or Fall Time
Pulse Width
Level
Line Name
(Maximum)
(Minimum)
UP DOWN
Select
0.25 usec
NS*
+2.5 +1.0
Backward
0.25 usec
9.5 usec
+2.5 +1.0
Go
0.25 usec
NS
+2.5 +1.0
Set Read Status
0.25 usec
10.5 usec
-#2.5 +1.0
Set Write Status
0.25 usec
7.9 usec
+2.5 +1.0
Rewind
NS*
NS*
+2.5 +1.0
Rewind-Unload
NS*
NS*
+2.5 +1.0
Metering Out
NS*
NS*
+2.5 +1.0
Write Bus
NS*
NS*
+0.6 +0.3
Command
Response
Rewind
Not Ready or Select & at LP
Rewind-Unload
Not Ready
Backward
Backward Status
Set Read Status
Select and Read Status
Set Write Status
(Not) Select and Read Status
*NS-not specified
Output Lines (To Tape Control)
Maximum
dc Voltage
Rise or Fall Time
Response Time
Level
Line Name
(Maximum)
(from Select)
UP
DOWN
Model 1, 2, 3
1 usec
2.0 usec
+2.5 +1.5
Select
&
T I Off
1 usec
6.8 usec
+2.5 +1.5
Select
&
at LP
1 usec
6.2 usec
+2.5 +1.5
Select
&
Read Status
1 usec
6.2 usec
+2.5 +1.5
Select
&
NS*
6.2 usec
+2.5 +1.5
Not File Protect
Backward
NS*
6.2 usec
+2.5 +1.5
Write Inhibit
See Note
See Note
+2.5 +1.5
Not Ready
NS*
NS*
+1.9 +1.0
Read Bus
NS*
NS*
0.1 vp/p@
180KC
Note: Determined by interblock gap (IBG) length
and the time necessary to reach full tape speed.
*NS- not specified
Figure 2. Interface Lines: Specifications