Maximum on-hook Tx power is increased from 10 to 12dB Maximum off-hook Tx power is increased from 7 to 12dB Maximum line rate is increased from 768 to 960 kbps. The 8312/8314 ReachDSL/MVL cards interoperate with either the 6310 MVL Modem or the 6350 ReachDSL Modem. Card...
Refer to one of the above installation documents to: — Install and set up the Hotwire DSLAM or GranDSLAM chassis — Install the Hotwire 8312/8314 MVL or ReachDSL/MVL card — Connect cables After the card is installed, there are configuration procedures that must be performed before you can begin to use the cards for Internet or intranet connectivity.
Page 3
Installing the 8312/8314 Card Procedure To install the Hotwire 8312/8314 MVL or ReachDSL/MVL Card in a Hotwire chassis: 1. If there is a filler plate covering the slot, remove it. 2. Insert the card into the card guides of the slot on the chassis. For the 8610 DSLAM, ensure that the components are facing up.
Page 4
8312 MVL and ReachDSL/MVL Card LEDs The following table describes the meaning and states of the LEDs on the Hotwire 8312 card faceplate. Type SYSTEM ETHERNET PORT Reach 8312 00-16865 LED is . . . Indicating . . . Green, Card functioning normally.
Page 5
Type SYSTEM ATM BUS DSL PORT Reach 8314 00-16866 8312-A2-GZ40-30 LED is . . . Indicating . . . Green, Card functioning normally. Winking describes a Winking recurring pulse when the LED is ON longer than OFF at a ratio of approximately 10:1.
Page 6
MVL and ReachDSL/MVL Card Technical Specifications Specifications Size Weight Approvals Safety Certifications Power Maximum Power Dissipation MVL 8312 MVL 8314 ReachDSL/MVL 8312 ReachDSL/MVL 8314 Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration * Criteria of technical specifications are subject to change without notice.