Personal Pattern Screen - IBM 3725 Manual

Communication controller stand-alone link tests
Table of Contents

Advertisement

Personal Pattern Screen
This screen allows you to create a personal pattern of up to 128 bytes.
Machine Status Area
I: IPL CCU/TSS
G:GCF/IPL PORTS
SP :CCU STOP
Q
:DATE/TIME'
L:LINE
FNCTN
C:CNTRL PGM PROC
ST:ccu START
T:TERMINATE'
E:ERROR LOG
H :MAINTENANCE
RS: CCU RESET'
. I
WRAP TEST'
PERSONAL PATTERN'
. 2
LINE INTF DPLY'
3
LINK TEST'
• ENTER PAIRS
OF
HEX CHARACTERS SEPARATED
BY
ONE BLANK'
•=>
00 01 02
Q.4
OS 10 20 40
ea
AS AC
AE cc CF DD EE
<==·
:==>
:==>
r=>
.• ENTER
C
WHEN PATTERN IS COMPLETE
==>'
PF3 :QUIT'
<==·
<=='
<=•'
<•=·
<=='
<=='
1. Enter the pattern as pairs of hexadecimal characters separated by a single
blank as shown on the screen above.
It is possible to send an empty (null) data pattern; to do this, simply enter 'C',
then press SEND. This may be useful if you wish to send an empty message
consisting only of a header and a trailer.
2. Enter 'C' followed by SEND to check the data for valid hexadecimal
characters.
3. The investigation mode screen or the statistical counters screen is displayed,
depending on the option specified in the OPTIONS screen.
( '
Notes:
1. You can return to the OPTIONS screen at any time by pressing PF3.
2. The IBM NCP and the Link Test Responder programs can both buffer a full
128 bytes. Other responders may be limited to less than 128 bytes; for
example, the Controller Load/Dump Program (CLDP)
is
limited to 32 bytes.
In this case, there
will
be· an INVALID DATA RECEIVED message if the
test message sent by the requester was longer than the limit.
2-10
3725 Communication Controller Stand-Alone Link Tests
~'
\
"