Installer Menus
Use the Installer Menus to make adjustments
Accessing the Installer Menu:
Installer Menus can be accessed by using the installer's remote control.
Just press and hold MENU (about 8 seconds) until the display changes,
then press 9, 8, 7, 6, then ENTER. To exit the Installer Menu:, press ENTER
again. Any changes you make will be stored in nonvolatile memory.
the Installer Menu: opens with item 03, VERT POS. Press the Up/Down
arrow keys to sequence through the various items. Or, access an item
directly by entering the line number, then pressing MENU. For example, to
access the Start channel/volume feature which is on line 11, press 11, then
MENU. To change a current setting use the Left/Right ADJ keys.
Using the Installer Menu:
Items 00-22 are immediately accessible only upon entering the Installer
Menu:. Their numbers, descriptions, ranges, factory default settings, and a
place for listing any changes made on-site are given below. A second sec-
tion of the Installer Menu: that is intended for qualified service technicians
only is not shown (items 23-52). Normally these items do not require
adjustment.
Items in the installer Menu:
I
tem
00
01
02
03
04
05
06
07
08
9
10
11
12
13
14
15
16
17
18
19
20
21
22
P A G E 3 4
Description
FACT MENU
PRESET PX
POWER MANAGE
VERT POS
HORZ POS
BAND/AFC
MIN VOLUME
MAX VOLUME
AC ON
KEY DEFEAT
STRT CH/VOL
HOSPITAL MODE
CHAN LOCK
GHOST CH.
SCAN MODE
TEXT MODE
SLEEP TIMER
ALARM
CH. OVER RIDE
OLD OCV
CAPTION LOCK
FUNCTION PRE
FEATURE LEVEL
1390-00 0.00 01
03 VERT POS
XX/XX/9X
Typical Installer Menu
Installer should leave item 1 FACT MODE
set to 0 (default). Items 23-52 are ser-
vice-type adjustments and only qualified
technicians having specialized test equip-
ment should access them.
Range
Fact. Set
0 - 1
0
0 - 1
1
0 - 7
0
0 - 30
15
0 - 45
29
0 - 7
0
0 - 63
0
0 - 63
63
0 - 1
0
0 - 1
0
0 - 255
255
0 - 1
0
0 - 1
0
0 - 1
0
0 - 3
0
0 - 1
1
0 - 1
1
0 - 1
1
0 - 1
1
0 - 1
0
0 - 1
0
0 - 1
0
0 - 1
1
13
TE11111111
Recommend. Setting
Leave default set 0
Leave default set 0
Leave default set 0
Set to 1 for Spectramate Systems
Leave default set 1
206-3488-O