Download Print this page

Mechanical Adjustments; General Note - Sony PS-LX510 Service Manual

Stereo turntable system

Advertisement

PS-LX510
SECTION 3
ADJUSTMENTS
3-1.
MECHANICAL
ADJUSTMENTS
Stylus Height Adjustment
1.
Put arecord.
2.
Press ARM
TRANSPORT
button (4) and move
the arm outside the record.
3.
Make
sure that clearance (A) is 4 — 7 mm
(3/16 — %%32 inches). If necessary, adjust the
stylus height adjustment screw.
4—7mm
Chis" — 9/32 ")
record
GENERAL
NOTE:
Do not let a strong light get in the groove of
photo
interruptor
during
mechanical
adjust-
ment. Otherwise, misoperation of stoppage or
moving may occur to the tonearm base.
stylus height
adjustment
screw
Lifter Height Adjustment
Adjust the lifter height adjustment
screw so that
the arm up/down coil position is 0 ~ 0.5 mm
(0" —
1/39") as shown below.
lifter
YY
Hise height adjustment
\A
Ke
ay
>
arm up/down coil (L301)
0-—0.5mm
(O" — 1/32")
arm magnet

Advertisement