8. Tracking gain
Connection
Oscilloscope
2U-2165 P.W.B.
Counter
TP (TE!)
TP (TE)
TP (GND)
Oscillator
Counter
@ 1.8 kHz
(£120 Hz)
1.8 kHz
@3Vp-p
(£120 Hz)
(+0.1V)
Step
. Set oscillator to 1.8 kHz/3 Vp-p.
@ DC range
X axis | 4 . Switch oscilloscope input to X-Y mode.
@ X-Y mode
. Adjust VR104 [T-GAIN] to symmetrize Lissajous
Y axis
Y axis
(6) Push
[4 OPEN/CLOSE