Zoom H4essential Operation Manual page 91

Handy recorder
Hide thumbs Also See for H4essential:
Table of Contents

Advertisement

5.
Set whether to record simultaneously with the H4essential.
Use
to select "Mode" and press
.
Setting
Audio I/F + REC
Audio I/F Only
NOTE
• "Audio I/F + REC" can be selected only when the sample rate is set to 44.1 kHz or 48 kHz. (→
sample
rate)
• All sample rate options can be used when "Audio I/F Only" is selected. The sample rate, which can be set
from the computer, smartphone or tablet, has 44.1 kHz, 48 kHz and 96 kHz options.
6.
Select the power supply.
Use
to select "Power" and press
press
.
Setting
USB
Batteries
. Then, use
The H4essential can record and play back even when it is being used
as an audio interface.
For details about this function, see
while using it as an audio
The H4essential will not record or play back when it is being used as
an audio interface.
. Then, use
Power will be supplied using USB bus power.
The batteries in the unit will be used.
91
to select the mode and press
Explanation
"Recording on the H4essential
interface".
to select the power supply and
Explanation
Setting the

Advertisement

Table of Contents
loading