Pioneer PD-X99M Service Manual page 42

Compact disc player
Table of Contents

Advertisement

Available languages

Available languages

PD-xX9S9SM
Check items/
Adjustment
specifications
Adjusting
Points
Adjustment procedure
Oscilloscope
Test
Setting
Points
ee
ee
Step
No.
0.14nS
| Lead of
/div
pin8 of
IC8 (TP6)
Main board
¢
Press TRACK FWD key and PLAY key by turns to close
assembly
the focus and spindle servos.
Turn AC-GND-DC
switch of Oscilloscope to DC.
Adjust vertical position of Oscilloscope so that the
waveform is positioned at the center.
Note:
It is not necessary to set the GND level at the
center of the oscilloscope in this adjustment.
Simply position the waveform at the center of
the
oscilloscope
with
the
vertical
position
control.
Waveform
is
positioned at
the center
Press PAUSE key to close the Tracking servo.
Waveform
is
positioned at
the center
Adjust VL1 (VCO coil) with a core driver so that the
waveform is positioned at the center.
*
Open and close the Tracking servo
by depressing
PAUSE key a few times and verify that the DC level
of the waveforms is not changed.
DC level of the
waveforms is not
changed
C27
cos
oh
R99 "98
5100
'
96 Re
ROS
z
Observe point
eo SPCC
C2090000
Fig. 7-8 VCO free-run frequency
observe
point
45