Lennox ZGB Series Unit Information page 8

Table of Contents

Advertisement

B LO WER DATA - 3 TON D IRECT DR IVE - SIN GLE PH ASE
ZGB036S4E - BASE UNIT
BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE.
FOR ALL UNITS ADD:
1 - Any factory installed options air resistance (heat section, economizer, etc.).
2 - Any field installed accessories air resistance (duct resistance, diffuser, etc.).
See page 29 for wet coil and options/accessory air resistance data.
DOWNFLOW
Blower Only
External
Static
Low and High Speed:
Press.
G (Pin 1)
in. w.g.
CFM Watts RPM
0
752
47
407
0.1
694
53
482
0.2
627
60
535
0.3
560
66
602
0.4
502
70
694
0.5
- - -
- - -
- - -
0.6
- - -
- - -
- - -
0.7
- - -
- - -
- - -
0.8
- - -
- - -
- - -
0.9
- - -
- - -
- - -
1.0
- - -
- - -
- - -
HORIZONTAL
Blower Only
External
Static
Low and High Speed:
Press.
G (Pin 1)
in. w.g.
CFM Watts RPM
0
737
50
416
0.1
676
56
485
0.2
606
62
560
0.3
536
68
628
0.4
475
73
683
0.5
- - -
- - -
- - -
0.6
- - -
- - -
- - -
0.7
- - -
- - -
- - -
0.8
- - -
- - -
- - -
0.9
- - -
- - -
- - -
1.0
- - -
- - -
- - -
Low Speed
1st Stage Heating:
W1 (Pin 2)
2nd Stage Heating:
Cooling:
W2 (Pin 2 and 4)
Y1 (Pin 2 and 5)
CFM Watts RPM
CFM Watts RPM
1127
142
623
1474
1089
150
668
1445
1049
158
713
1414
1007
167
760
1389
965
175
805
1350
923
183
849
1314
881
191
891
1287
826
201
945
1251
785
208
983
1219
646
190
836
1181
618
195
863
1147
Low Speed
1st Stage Heating:
W1 (Pin 2)
2nd Stage Heating:
Cooling:
W2 (Pin 2 and 4)
Y1 (Pin 2 and 5)
CFM Watts RPM
CFM Watts RPM
1255
179
671
1539
1221
188
701
1509
1179
199
749
1475
1138
209
795
1446
1096
219
840
1411
1053
229
883
1375
1012
239
925
1341
960
250
975
1305
918
259
1012
1263
873
268
1060
1216
826
277
1094
1180
1st Stage Heating:
W1 (Pin 3)
2nd Stage Heating:
W2 (Pin 3 and 4)
CFM Watts RPM
294
803
1664
404
304
835
1636
419
314
871
1613
430
323
898
1579
445
335
940
1556
454
347
978
1522
466
356
1008
1488
475
367
1045
1442
485
377
1078
1408
490
389
1117
1363
494
400
1152
1317
494
1st Stage Heating:
W1 (Pin 3)
2nd Stage Heating:
W2 (Pin 3 and 4)
CFM Watts RPM
311
794
1666
386
321
827
1637
402
334
866
1614
414
344
896
1580
430
357
935
1545
445
369
972
1510
457
381
1010
1475
468
393
1047
1441
478
408
1090
1394
487
423
1138
1360
492
435
1173
1314
496
Page 8
High Speed
Cooling:
Y1 (Pin 3 and 5)
CFM Watts RPM
887
1474
294
803
922
1445
304
835
949
1414
314
871
987
1389
323
898
1011
1350
335
940
1045
1314
347
978
1076
1287
356
1008
1114
1251
367
1045
1140
1219
377
1078
1170
1181
389
1117
1196
1147
400
1152
High Speed
Cooling:
Y1 (Pin 3 and 5)
CFM Watts RPM
850
1588
340
818
886
1560
350
849
914
1527
363
885
954
1493
376
921
991
1460
388
958
1027
1426
401
993
1060
1393
413
1029
1090
1359
426
1064
1128
1326
438
1100
1153
1281
454
1146
1183
1247
466
1181
Free Cooling
Low and High Speed:
Y1 (Pin 1 and 5)
CFM Watts RPM
1474
294
803
1445
304
835
1414
314
871
1389
323
898
1350
335
940
1314
347
978
1287
356
1008
1251
367
1045
1219
377
1078
1181
389
1117
1147
400
1152
Free Cooling
Low and High Speed:
Y1 (Pin 1 and 5)
CFM Watts RPM
1539
311
794
1509
321
827
1475
334
866
1446
344
896
1411
357
935
1375
369
972
1341
381
1010
1305
393
1047
1263
408
1090
1216
423
1138
1180
435
1173

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zgb036Zgb048Zgb060Zgb074

Table of Contents