For the
electrical
installer
Electrical connection
Local and national electrical regulations must be observed.
All instructions given by the Electricity Board must be followed
carefully when connecting the oven to the mains supply.
This is a job for a qualified and approved electrician. The appli¬
ance is rated for 240 volts single phase and must be permanently
connected.
The cooker must be installed in such a way that it can be easily
disconnected from the mains supply before servicing, e.g., by an
adjacent cooker control unit.
Sufficient cable should be left to enable the appliance to be re¬
moved from the housing unit whilst still connected to the mains
supply.
WARNING - THIS APPLIANCE MUST BE EARTHED!
Voltage and current
Please ensure that the voltage and current indicated on the rating
plate agrees with the voltage of your electricity supply. 220-240
volts i.e., 220-240 V a.c.
1. Open the cover of the terminal box sideways as illustrated in
fig. G.
2. Pass cable through the grommet in the lower back panel and
the cable clamp.
3. Connect the wires to the terminals in accordance with the dia¬
gram. Ensure that links are correctly positioned between ter¬
minals (5 or 6 way terminal block). The length of the earth con¬
ductor must be adequate to ensure that in case of the cable
clamp breaking the earth wire is subject to mechanic strain
only after the live wires.
6