Connecting the module to the KSU
Before you begin
,
ensure a Norstar station port is available at the distri-
bution block and all line appearances are removed from the StarTalk
Flash DN(s) prior to booting the unit. For instructions on installing a
station port and removing line
appearances,
refer to the Norstar
Installation Guide that came with the Norstar KSU.
To connect the module:
1 .
Locate the distribution
block.
2.
Ensure there is one available station port at the distribution
block.
3.
Mount the teladapt jack next to the distribution block.
4.
Use twisted pair station wire to connect the teladapt to a free
station port in the distribution block.
5.
Use a working Norstar telephone to test the port.
6.
Connect one end of the teladapt to the station port at the side of
the module
.
Connect the other end to the teladapt jack. Do not use
a teladapt cord longer than 4.5 m (about 14
ft)
.
StarTalk Flash Installation Guide