4.3 ERROR CODES

4.3.2 ERROR MESSAGES OF HISTORY LOGS

If tightening work is not complete successfully, you can check the error description from
the history log displayed on the Tool Manager software. (For how to browse history logs,
Refer to 2.2.12
Category
Torque
1 Torque
exceeded
Torque
2 Torque
insufficient
Before snug
3 Angle
angle exceeded
Before
4 Angle
snug angle
insufficient
After snug
5 Angle
angle exceeded
After snug
6 Angle
angle
insufficient
7 Error
Rundown error
EN
.)
Error message
• The measured torque of the
tool exceeded the upper-limit
torque setting.
• The member conditions do not
suit the tool.
• The measured torque of the
tool at the time of work stop is
less than the lower-limit torque.
• The member conditions do not
suit the tool.
• The angle before snug in the
middle of work exceeded the
upper-limit setting.
• The angle before snug at the
time of work stop is less than
the lower-limit setting.
• The angle after snug in the
middle of work exceeded the
upper-limit setting.
• The angle after snug at the
time of work stop is less than
the lower-limit setting.
• A shut-off stop was made
within the rundown error time
setting.
Cause
- 337 -
Continued to the next page
Action
(for unintended cause)
• Check the settings.
• Reconsider the member
conditions.
• Disable the upper-limit torque
setting.
• Check the settings.
• Reconsider the member
conditions.
• Disable the lower-limit torque
setting.
• Check the settings (including
the snug point setting).
• Reconsider the member
conditions.
• Disable the upper-limit setting.
• Check the settings (including
the snug point setting).
• Reconsider the member
conditions.
• Disable the lower-limit setting.
• Check the settings (including
the snug point setting).
• Reconsider the member
conditions.
• Disable the upper-limit setting.
• Check the settings (including
the snug point setting).
• Reconsider the member
conditions.
• Disable the lower-limit setting.
• Check the settings (shut-off
torque and rundown error time
setting).
• Reconsider the member
conditions. (The stop might be
caused by an abnormal load.)
• Disable the rundown error
setting.