Atte Ry; Sa F Et Y Co N S Id E R At I O N; Hp M Odel 435 Β A; R Ecommend Ed Test Equipment - HP 435B Operating And Service Manual

Power meter
Table of Contents

Advertisement

M
odel 435 Β
Gen era l Informati on
1-4.
OP TIO N S
1-9 .
E
Q U IPMEN T AVAILA BLE
1-5.
Battery
Th e HP
M
od e l 11683Α
R
an ge Calibrator i s reco m-
The
M
od e l 435 Β ,
O
pt ion 001
P
ow er Meter is sup-
me nded for performance testing, adju sting a nd
pli e d with α rechargea ble battery
t
hat provides up
t r o ubl es hooting the
P
o w er Mete r. Th e
P
ow er
to 16
h
ours continuous ope ration from α full
Mete r's r a nge-to-range accurac y and a u to-zero
c harge.
ope ratio n can easily be
v
erified with
t
h e ca libra-
to r.
I
t al so h as t h e ca pa bility of s upplying α full
If
t
he
P
ower Meter w as purch ased wi tho ut the
sca le test si gnal fo r each range.
b attery
o
ption,
i
t may be ordered in kit
f
o rm unde r
HP part number 00435-60012 . The kit includes the
An e x te nder board (HP part numbe r 5060-0630)
batte ry, t h e battery c lamp, α 6-32 χ 1/2-inc h pan
may b e
u
se d to pl ace the Α 4 assembly printe d
head m ac hine screw and installation inst ructions .
c ir cuit b oa rd in α pos iti o n t h at all o w s easy access
to test p oints and co mpon ents .
1-6 .
Input-Output Options
O ption 002 . Α
r
ear p ane l input connector i s
co nnected in parallel wi th
t
he fro nt pa nel input
connector .
Option 003 . Α
r
ear pan el input connector is con-
nected in parallel with
t
he front panel inpu t con-
nector . Α rear panel PO WER REF
O
UTPUT con -
necto r r epl aces the sta nd ard front p ane l con -
necto r.
Option 004 . The 1 .5 metre (5
ft.)
power sen sor cabl e
i
s not shipped with
t
he
P
ower M eter .
1-7.
ACCESSO RI E S SUPPL I ED
The accesso ri es supplied with
t
he
P
ower Mete r a r e
shown in Figure 1-1 .
1-10 . RE CO MMEN D ED T E ST
E
Q U IPMEN T
α.
The 1.5 metre (5- foot) pow er senso r ca bl e,
HP part number 11730Α ,
i
s
u
sed to couple t h e
power sensor to the
P
ower Mete r. The 1.5 met r e
cable
i
s omitted when
O
ptio n 004
i
s ordered .
b.
The lin e power cable may be supplie d in sev-
eral confi gurations .
R
efer to the par agraph e n-
titled Power Cables in Section II.
1-8 .
E
QU IPMENT RE Q U I RE D BU T NOT
SUPPLIE D.
To
f
orm α complete RF p owe r m eas urement sy s-
tem , α power senso r, s u c h as th e HP
M
od el 8481 Α,
must be connected to t h e
P
ower Mete r via the
power sensor cable.
Th e
f
o llow ing tabl e li sts t he po wer sen sor cabl e
accessori es a nd
t
heir l e ngths t hat ar e a v ail abl e
f
or use wit h
t
he
P
o w e r Mete r . O rd e r op tio n 004 if
t he standard 1 .5 metre cable
i
s not d es ir ed wi t h α
ca bl e accesso ry.
P
ower Se nsor Ca ble Accessory
Cab le
L
engt h
3 .1 m (10
f
t)
6 .1 m (20 ft)
15.2 m (50
f
t)
30 .5m (100
f
t)
61 .Om (200
f
t)
Th e test equipment s ho wn in Table 1-2
i
s recom-
mende d for u se du ring p erform an ce testing, adj ust-
ments and
t
roubles hoot ing. To e nsur e o ptimum
p e rform ance o f
t
he
P
o w e r Mete r, t he sp ecifi ca-
t ion s o f α s ub sti tute inst rum ent mu st equal or
e
x ceed th e criti cal spec ifi cati on s s hown in
t
h e
table.
1-11 . SA FE TY CO N SID ER ATION S
Th e
P
ow er Mete r i s α Safet y C l ass Ι instrument
(pro vid ed with α pr otectiv e ear t h terminal) . Thi s
instrum ent has b een des igne d according to inte r-
n ational sa fet y sta nda rds and has been suppli e d
in sa fe condition.

Advertisement

Table of Contents
loading

Table of Contents