E52: No signal from motor tachometric generator (second part)

E52
Cycle interrupted after 5 attempts during the cycle, immediately if recognised at the start of
Checks to perform:
The motor never runs
To check the wiring, measure
(Ω) between the following wiring
connectors of the main circuit
board (see fig. 4) and compare
them with
the correct ones
(see pag. 47: point 4 - motor
parameters)
- between J11-2 and J11-5,
a value as in point 4 - B (Stator)
must be found
- between J11-1 and J11-5,
where featured, a value
as in point 4 – D must be found
(half field stator).
- between J11-3 and J11-4,
a value as in point 4- C (rotor)
must be found.
Are the values correct?
YES
Replace the circuit board and
repeat the diagnostic cycle to
check for any further alarms.
MAIN CIRCUIT BOARD
ROTOR
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
the cycle or during diagnostics.
Check the motor as
NO
Check/replace the
wiring and repeat the
diagnostic cycle to
check for any further
HALF FIELD STATOR
TACHOMETER
FULL FIELD STATOR
!
Check that all the connectors are correctly inserted
on page 47.
NO
Is the motor ok?
YES
alarms.
J14
J5
J4
GND
Fig. 4
!
46/69
Replace the motor and
repeat the diagnostic
cycle to check for any
further alarms.
J11
J13
J10
J6
If there are burns on the circuit board,