Troubleshooting Based On Alarm Codes; E11: Water Fill Difficulty During Washing - Electrolux EWM09312 Service Manual

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

6 TROUBLESHOOTING BASED ON ALARM CODES

E11
Checks to perform:
Run the diagnostic cycle and fill all the trays with water (phases 2,3,4)
N
O
Is the drain tube positioned
correctly and not causing the siphon
Is the washing machine's water
circuit efficient (leaking)?
Is the pressure switch's water circuit
efficient (leaking/clogged)?
Replace the main circuit board and repeat the diagnostic cycle to check for any further alarms.
Is one or are all the solenoid valves not working?
YES
Is the resistance measurement of the solenoid
valve approximately 3.5÷4.5 KΩ? (Measure it
directly on the solenoid valve without wiring)
-(see fig. 3)-
YES
Reconnect the connector and measure
approximately 3.5÷4.5 KΩ on the solenoid valve
wiring connector on the circuit board side (fig. 4):
Between J13-1 and J13-3 washing
Between J13-4 and J13-6 pre-wash
Is the solenoid valve wiring ok?
YES
Replace the main circuit board and repeat the
diagnostic cycle to check for any further alarms.
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls

E11: Water fill difficulty during washing

Maximum water fill time for every level of the pressure switch
(the time is reset every time the level is achieved)
Are all the trays filling with water?
YES
effect? (fig. 1)
YES
YES
(fig. 2)
YES
!
check that all the connectors are correctly inserted
Repair the drain circuit and repeat the
NO
diagnostic cycle to check for any further alarms.
Repair the water circuit and repeat the
diagnostic cycle to check for any further alarms.
NO
Repair the water circuit of the pressure switch
and repeat the diagnostic cycle to check for
NO
any further alarms.
Check whether the tap is open, if the water
pressure is too low and make sure the tubes are
NO
connected and not kinked
Replace the solenoid valve and repeat the
NO
diagnostic cycle to check for any further alarms.
Replace/repair the wiring and repeat the
NO
diagnostic cycle to check for any further alarms.
If there are burns on the circuit board,
!
20/69
E11
see page 67
599 75 18-74 Rev.00