Troubleshooting

Problem
Device doesn't
start
Strong vibrations
Laser does not
work
Loud squeaking
noise
18
Possible Cause
Emergency stop switch (5) has
been triggered
No mains voltage
Main circuit breaker is tripped
On switch (2) / off switch (1)
defective
Motor faulty
Motor unit (13) not fixed in
place
Bit not centrally clamped
Batteries empty
V-belt tension is too high
Damaged V-belts (29)
Damaged pulley
Error correction
Reactivate the emergency stop
switch (5) by turning it. Press the on
switch (1) to restart the device
Check the socket, mains supply
cable, cord, mains plug; if necessa-
ry, have them repaired by a quali-
fied electrician.
Check the main fuse
Repair by Customer Care
Repair by Customer Care
Check V-belt tension and tighten the
locking screw (12)
Check the bit in the drill chuck (4)
Replace batteries (see "Replacing
laser batteries")
Check V-belt tension
Check V-belts (29)
Check pulleys

Advertisement