Insert the Rosemount Annubar

Procedure
1. Align the flow arrow on the head with the direction of flow.
Assemble the bar to the mounting flange using a gasket, bolts,
and nuts.
2. Tighten the nuts in a cross pattern to allow even compression
of the gasket.
3. If opposite side support is threaded, apply an appropriate
thread sealing compound to the support plug threads and
tighten until no leakage occurs.
4. If opposite side support is a socket weld fitting, insert the
plug into the socket-weld outlet fitting until the parts contact.
Retract the plug 1/16 in. (1.6 mm) remove the Rosemount
Annubar Sensor and apply fillet weld per local codes.