Axis Ex Series Installation Manual page 11

Hide thumbs Also See for Ex Series:
Table of Contents

Advertisement

11 RS485 terminal
Pin 1: A
Pin 2: B
12 Auxiliary OUT terminal
Pin +: Auxiliary OUT +48 V DC 14.4 W max
Pin –: Auxiliary OUT 0 V DC
13 I/O terminal
Pin 1: DC ground, 0 V DC
Pin 2: DC output, 12 V, max load 50 mA
Pin 3–4: Digital input or supervised input, 0 to max 30 V DC
Pin 5–6: Digital output, 0 to max 30 V DC, open drain, 100 mA
14 AC mains IN terminal
Pin N: Supply neutral
Pin L: Supply live
Connect the fixed camera wiring to the connection terminal at the back of the device.
1. Removing the 6 M5x12 A4 socket head screws. Use the included stainless steel bits.
2. Remove the back cover. Carefully pull the back cover off.
3. Route the cables through threaded entry points and suitably certified glands.
CAUTION
Take extra care to not damage the joint surface.
WARNING
Earthing connection must be minimum 14 AWG (2 mm²) conductor with green and yellow
insulation. Connect through the M4 earth stud using the supplied crimp ring terminal.
Tighten with a 7 mm ring spanner or socket.
The terminal plugs can be disconnected to allow easy termination outside of the enclosure. For TB1
and TB2 use wire between 18 - 12 AWG / 0.8 - 3.0mm².
WARNING
Only one wire should be connected to each clamping point.
An external earth connection point is available for up to 11 AWG (4 mm²) connection. When used,
it should be used with a crimp ring terminal.
Use an RJ45 connector (CAT5 or higher) for network connection. Optionally, an SFP slot is available
for an alternative network connection, this port utilizes various SFP modules including fiber optic.
You can also use the RJ45 network connection to supply power to the housing. When used with
Power over Ethernet (PoE), the Power Sourcing Equipment (PSE) shall comply with IEEE 802.3bt
type 3 Class 6 PoE.
11
AXIS Ex Series