Checks And Adjustments - Carrier 58HDX Installation, Start-Up, And Operating Instructions Manual

Condensing gas furnace
Hide thumbs Also See for 58HDX:
Table of Contents

Advertisement

A07729
Fig. 42 - Side Mounted Filter Rack
Filter Installation using Optional Filter Rack
When
installing or removing a bottom mounted filter, slide the
two side filter clips to the back of the furnace BEFORE installing
or removing. This will allow the filter to clear the front raised
edge of the furnace. Insert filter into side clips first and push filter
back until it is fully engaged into back clip. When
filter is in
place, slide clips back into place midway on filter as shown in
Fig. 43
and Fig. 44.
Center Clip
side-to-side
a
Se
9" (152.4mm),_
25-24-18-1
Slide filter clips towards back before removing
A07691
Fig. 43 - Bottom Mounted Filter Rack
ao
«.
11/5 in.
a
oN
eo °
.
_
<< ee
D
oN
3in(76.2)
or
oN
~
NN
NN
oN
Ne
oS
A.
11g in.(31.8)
SON
a
Ab
SO
SJE
NSN
AF
A SN,
26 Ga. Galvanized
Steel
NS
>
FAST part number 1008482
Ne
in (16 in.(27)
07730
Fig. 44 - Filter Clip Construction
Refer to Fig. 45 and for guidelines to install filters. Furnaces
which require larger filter media and have limited clearances on
one side of furnace, require a standoff filter rack, see Fig. 45,
available from your distributor.
Using Optional
Standoff Filter
Rack
7
A07731
Fig. 45 - Standoff Filter Rack
Addition Of Air Conditioning
When a refrigeration coil is used in conjunction with this unit, it
must be installed parallel with or on the discharge side of the unit
to avoid condensation
on the heat exchanger. All furnaces are
designed with a break-away duct flange on the supply air side of
the furnace. This allows for installation in the horizontal right or
downflow applications. The coil installation instructions must be
consulted
for proper
coil location
and installation procedures.
With a parallel flow arrangement, dampers must be installed to
prevent
chilled
air
from
entering
the
furnace.
If manually
operated dampers are used, they must be equipped with a means
to prevent operation of either unit unless the damper is in full heat
or full cool position.
A 3" (76 mm)
clearance
is required
on the right side of the
furnace
in order to run the condensate
drain line.
Copper
or
plastic tubing may be used for the condensate drain line.
4
CAUTION
UNIT OPERATIONAL
HAZARD
Failure to follow this caution may
result in improper unit
operation.
This
furnace
is
not
approved
for
use
with
"N"
style
evaporator coils.
If installed with an "N" style evaporator
coil, improper limit operation may occur.
CHECKS AND ADJUSTMENTS
NOTE:
Verify the input rate of the furnace.
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,
death and /or property damage.
Turn OFF gas at shut off before connecting manometer.
40