4-10. Connecting 1-Phase Input Power (Continued)
!
Turn Off welding power source, and
check voltage on input capacitors
according to Section 9-1 before
proceeding.
!
Installation must meet all National and
Local Codes − have only qualified per-
sons make this installation.
!
Disconnect and lockout/tagout input
power
before
connecting
conductors from unit. Follow estab-
lished procedures regarding the in-
stallation and removal of lockout/
tagout devices.
!
Make input power connections to the
welding power source first.
!
Always
connect
green/yellow conductor to supply
grounding terminal first, and never to
a line terminal.
.
The Auto-Line circuitry in this unit
automatically links the power source to the
primary voltage being applied. Check input
voltage available at site. This unit can be
connected to any input power between 208
and 575 VAC without relinking the power
source.
See rating label on unit and check input
voltage available at site.
Notes
1
Input Power Conductors (Customer
Supplied Cord)
Select size and length of conductors using
Section 4-8. Conductors must comply with
national, state, and local electrical codes. If
applicable, use lugs of proper amperage
capacity and correct hole size.
Three Conductor Power Cord Preparation
2
Black And White Input Conductors
input
(L1 And L2)
3
Red Input Conductor
4
Insulation Sleeving
5
Green Or Green/Yellow Grounding
Conductor
6
Electrical Tape
green
or
Insulate and isolate red conductor as shown.
Welding Power Source Input Power
Connections
7
Strain Relief
Install strain relief of proper size for unit and
input conductors. Route conductors (cord)
through strain relief and tighten screws.
Connect input conductors as shown in
illustration.
8
Current Transducer
9
Welding Power Source Grounding
Terminal
10 Welding Power Source Line Terminals
Route green or green/yellow grounding
conductor through current transducer and
connect to welding power source grounding
terminal first. Then connect input conductors L1
and L2 to welding power source line terminals.
Reinstall side panel onto welding power source.
Disconnect
Device
Input
Connections
11 Disconnect Device (switch shown in
OFF position)
12 Disconnect Device (Supply) Grounding
Terminal
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
13 Disconnect Device Line Terminals
Connect input conductors L1 and L2 to
disconnect device line terminals.
14 Over-current Protection
Select type and size of over-current
protection
using
Section
disconnect switch shown).
Close and secure door on line disconnect
device. Follow established lockout/tagout
procedures to put unit in service.