Advanced - Bosch DINION 7100i IR NBE-7702-ALX User Manual

Hide thumbs Also See for DINION 7100i IR NBE-7702-ALX:
Table of Contents

Advertisement

48
en | Configuration
HSTS
Select this option to use the web security policy HTTP Strict Transport Security (HSTS) to
provide secure connections.
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on this port. To allow only
encrypted connections, set the Off option to deactivate the port.
Discovery port (0 = Off)
Enter the number of the port that you want to discover.
To deactivate the port, enter 0.
Interface mode ETH
If necessary, select the Ethernet link type for interface ETH. Depending on the device
connected, it may be necessary to select a special operation type.
Network MSS [Byte]
Set the maximum segment size for the IP packet's user data here. This gives the option to
adjust the size of the data packets to the network environment and to optimize data
transmission. In UDP mode, comply with the MTU value set below.
Network MTU [Byte]
Specify a maximum value in bytes for the package size (including IP header) to optimize data
transmission.
Click Set to apply the changes.
4.7.3

Advanced

RTSP
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The
standard RTSP port is 554. Select Off to deactivate the RTSP function.
802.1x
Authentication
If a RADIUS server is employed in the network for managing access rights, authentication must
be activated here to allow communication with the unit. The RADIUS server must also contain
the corresponding data.
To configure the unit, you must connect the camera directly to a computer using a network
cable. This is because communication via the network is not enabled until the Identity and
Password parameters have been set and successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying the camera.
Password [EAP-MD5]
Enter the password that is stored in the RADIUS server.
Certificates [EAP-TLS]
If any certificates are already uploaded at the client level or at the server level, they show
here.
Click Configure to be redirected to the Certificates page in order to add or configure any
existing certificates.
2023-06 | V02 | F.01U.390.686
User manual
DINION 7100i IR
Bosch Security Systems B.V.

Advertisement

Table of Contents
loading

Table of Contents