I N S TA L L AT I O N
I N S T R U C T I O N S
E L E C T R I C A L
R E Q U I R E M E N T S
This appliance must be installed in accordance
with National Electrical Codes, as well as all
state, municipal and local codes. The correct
voltage, frequency and amperage must be
supplied to the appliance from a dedicated,
grounded circuit which is protected by a
properly sized circuit breaker or time delay
fuse. The proper voltage, frequency and
amperage ratings are listed on the product
rating plate, located on the underside of the
cooktop.
The cooktop is provided with a terminal box
and 4' (1.2 m) conduit consisting of two insu-
lated hot lead conductors (copper) and one
insulated ground conductor (copper). Refer to
the wiring diagram below.
For Electrical Installation – attach the
conductors to the residence wiring in accor-
dance with National Electrical Codes and all
state, provincial, municipal and local codes.
L1
L2
GROUND
Wiring diagram
Dimensions in parentheses are in
millimeters unless otherwise specified.
The complete appliance must be properly
grounded at all times when electrical
power is applied.
Do not ground the appliance with the
neutral (white) house supply wire. A
separate ground wire must be utilized.
If aluminum house supply wiring is
utilized, splice the appliance copper wire
to the aluminum house wiring using
special connectors designed and agency
certified for joining copper and aluminum.
Follow the connector manufacturer's
recommended procedure carefully.
Improper connection can result in a fire
hazard!