Commissioning, inspection, maintenance

Adjusting the burner

The combustion heating output of the burner must not
exceed the permissible combustion heating output of
the boiler. Adjust the maximum gas or oil throughput of
the burner to the rated boiler heating output.
Use of low-NO
burners
x
Incorrectly adjusted low-NO
els of vibration and resonance during operation. This
phenomenon can result in damage to the thermal insu-
lation in the area of the boiler door/doors, the cleaning
aperture covers and the flue gas collectors.
The information and values in the tables relate to the
following general conditions:
O
content in dry flue gas
2
For natural gas: 3.0
%
For EL fuel oil: 3.0
%
Flow/return temperature: 80/60 °C
100
load
%
Max. pressure drop on the flue gas side
Boiler type M148
Boiler size
Rated heating output at
110 °C
For natural gas
For EL fuel oil
Max. pressure drop on
the flue gas side at 110
°C
For natural gas
For fuel oil EL
Tab. 8
Boiler type M62C
Boiler size
Rated heating out-
put at 110 °C
For natural gas
MW
For EL fuel oil
MW
Max. pressure
drop on the flue
gas side at 110 °C
For natural gas
mbar
For fuel oil EL
mbar
Tab. 9
Boiler type M64B
Boiler size
Rated heating output at 110 °C
For natural gas
For EL fuel oil
26
All manuals and user guides at all-guides.com
burners increase the lev-
x
by vol.
by vol.
1
2
MW
0.65
0.85
MW
0.65
0.85
mbar
2.9
4.4
mbar
2.5
3.9
1
2
3
2.30
2.60
2.90
2.30
2.60
2.90
8.5
8.9
9.7
8.1
8.5
9.1
MW
10.00
MW
Burner operating and service instructions
To prevent vibrations and resonances:
Adjust the burner correctly.
Prevent "hard flames".
Carefully monitor the operation of the burner during
the 1st year of operation.
Rectify operating faults immediately.
Installation altitude: < 500 m above sea level
Combustion air temperature: 25 °C
Applicable to M62C:
O
content in dry flue gas
2
For natural gas: 2.1
For EL fuel oil: 2.7
3
4
5
6
1.10
1.40
1.80
2.30
1.10
1.40
1.80
2.30
7.0
8.2
5.5
8.2
6.2
7.1
4.8
7.2
4
5
6
7
3.20
3.60
4.20
4.50
3.20
3.60
4.20
4.50
10.4
12.5
14.1
13.3
9.8
11.9
13.4
12.6
3
4
5
12.00
14.00
9.12
10.37
11.61
by vol.
%
by vol.
%
7
8
9
A
2.90
3.50
4.20
5.00
2.90
3.50
4.20
5.00
10.0
11.0
9.4
10.5
8.9
9.6
8.1
9.0
8
9
A
B
5.20
6.00
6.75
8.00
5.20
6.00
6.75
8.00
15.0
16.5
17.2
13.2
14.2
15.5
16.3
12.4
6
7
8
16.00
18.00
20.00
13.09
14.17
16.02
B
6.00
6.00
11.2
10.1
C
8.80
8.55
12.3
10.8
9
21.50
16.90