I N S TA L L AT I O N
I N S T R U C T I O N S
G A S L E A K
T E S T I N G
Perform a gas leak test each time the LP gas
cylinder is connected to the regulator and any
time part of the gas system is disconnected or
replaced. This applies to natural gas as well as
LP gas. Perform a leak test at least once each
year whether the LP gas cylinder has been
disconnected or not.
Test for leaks at the cylinder valve, cylinder
welds, regulator (especially attached to
cylinder valves), hose and connections.
NO SMOKING! Do not use or permit sources
of ignition in the area while doing a leak test.
Conduct leak tests outdoors in a well venti-
lated area.
Do not use a flame, such as a lighted match to
test for leaks. Use only a soap and water
solution for leak testing, such as half liquid
soap and half water.
Have a dealer check the cylinder for deteriora-
tion when the tank is filled in accordance with
regulations. Immediately replace cylinder if
any deterioration is found.
Testing for gas leakage of the appliance
shall be conducted according to the
manufacturer's instructions.
Dimensions in parentheses are in
millimeters unless otherwise specified.
L E A K T E S T I N G P R O C E D U R E
Check that all the control knobs are in the
OFF position.
Mix a solution of half liquid soap and half
water.
Turn the cylinder valve knob counterclock-
wise one turn to open.
Apply the soap and water solution on joints
of the gas delivery system.
Bubbles in the soap and water solution
indicates that a leak is present.
Stop a leak by tightening the loose joint or
by replacing the faulty part with a replace-
ment part recommended by the manufac-
turer. Do not attempt to repair the cylinder
valve if it should become damaged. The
cylinder must be replaced.
If you are unable to stop a leak, shut off the
gas supply at the cylinder valve. Remove
the cylinder from the grill. Call a Wolf
authorized service center. Do not use the
appliance until the leak is corrected.
Push in and turn any control knob to the on
position to release pressure in the hose and
manifold.
Turn OFF the control knob.
Do not store a spare LP gas cylinder
under or near this appliance.
Never fill the cylinder more than 80% full.
If this information is NOT followed
exactly, a fire causing death or serious
injury may occur.