Iridium Arc Bar Pro 1215 Manual

Ip65 12x15w rgbw led

Advertisement

Quick Links

iridium
Arc Bar Pro 1215 IP65 12x15W RGBW LED
Product code: 113531

Advertisement

Table of Contents
loading

Summary of Contents for Iridium Arc Bar Pro 1215

  • Page 1 Arc Bar Pro 1215 IP65 12x15W RGBW LED Product code: 113531...
  • Page 2: Cable Connectors

    CABLE CONNECTORS Product Overview Cabling must have a male XLR connector on one end and a female XLR connector on the other end. DMX connector configuration GROUND caution:Do not allow contact between the ground and the fixture’s chassis ground. Grounding the ground can cause a ground loop, and your fixture may perform erratically.
  • Page 3: Mechanical Specification

    Mechanical Specification RDM---Remote Device Management RDM is a wild version of the DMX512-A protocol, allowing dimming stations and other control devices to be discovered through a DMX512 network, and then configuring, status monitoring, and managing intermediate and line end devices. It allows two-way communication between the lighting device or system controller and the connected RDM compatible device through the standard DMX.
  • Page 4 INFORMATION-In this menu, you can learn about the information of RDM, software and hardware of the light. 1.Press “ENTER” and then press “UP” or “DOWN” to “INFORMATION”. Packaging: Thanks for your purchasing the ARC BAR PRO STROBE. All the lights have 2.Press “ENTER”...
  • Page 5 Features Mounting ● Light Source: 360pcs white led,192pcs RGB 5050 1W LED When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit ● Beam angle: 90° must be secured with a secondary safety attach-ment, e.g.
  • Page 6: Slave Mode

    Displayer introduction ① ② ③ temp:043 ④ ADDRESS ⑤ Key lock open MENU DOWN ENTER 1. DMX means the light is in the DMX mode.Similarly,SLAVE means the light is in the SLAVE mode. 2. The color of the point shows the condition of signal transmission. Green represents the good condition, while red represents the signal is interrupted.
  • Page 7: Programme Menu

    DMX MODE-In this menu,you can connect several pieces of lights with DMX cable and control them with the control console. Programme Menu Press ”ENTER” and then press “UP” or “DOWN” to ”Address” or “DMX Channel” and press “ENTER”. 1) “XXX” will be showed in “Address”, "XXX” means the Address 001-512. You can press “UP” or “DOWN”to select the address you desired.
  • Page 8 000 - 255 White section9 Curve 1 000 - 255 White section 10 Curve 2 Dimmer Curve 000 - 255 White section 11 Curve 3 000 - 255 White section 12 Curve 4 000 - 255 Red13 Dimmer Speed Halogen 000 - 255 Green13 000 - 255...
  • Page 9: Dmx Control Mode

    DMX control mode 3 CHANNELS Channel Value Function 000 - 255 Flash intensity 000 - 255 Flash Duration 000 - 255 Flash Rate 10 CHANNELS Channel Value Function 000 - 255 Master Dimmer 000 - 255 Flash intensity 000 - 255 Flash Duration 000 - 255 Flash Rate...
  • Page 10 22 CHANNELS Channel Value Function 000 - 255 Master Dimmer 000 - 255 Flash intensity 000 - 255 Flash Duration 000 - 255 Flash Rate 000 - 255 Color marco 0-51 000 - 255 Frost Glasses 000 - 255 Red 1 000 - 255 Green1 000 - 255...
  • Page 11 36 CHANNELS Channel Value Function Master Dimmer 000 - 255 000 - 255 Flash intensity 000 - 255 Flash Duration 000 - 255 Flash Rate 000 - 255 Color marco 0-51 000 - 255 Frost Glasses 000 - 255 Red 1 000 - 255 Green1 000 - 255...
  • Page 12 000 - 255 Green6 000 - 255 Blue6 000 - 255 Red 7 000 - 255 Green7 000 - 255 Blue7 000 - 255 Red 8 000 - 255 Green8 000 - 255 Blue8 000 - 255 auto 1-31 000 - 255 auto speed 50 CHANNELS Channel...
  • Page 13 000 - 255 Green4 000 - 255 Blue4 000 - 255 Red 5 000 - 255 Green5 000 - 255 Blue5 000 - 255 Red 6 000 - 255 Green6 000 - 255 Blue6 000 - 255 White section 1-2 000 - 255 White section 3-4 000 - 255...
  • Page 14 000 - 255 Red 12 000 - 255 Green12 000 - 255 Blue12 000 - 255 auto 1-31 000 - 255 auto speed 92 CHANNELS Channel Value Function 000 - 255 Master Dimmer Flash intensity 000 - 255 000 - 255 Flash Duration 000 - 255 Flash Rate...
  • Page 15 000 - 255 Blue5 36 CHANNELS 000 - 255 Red 6 Channel Value Function 000 - 255 Green6 000 - 255 Master Dimmer 000 - 255 Blue6 000 - 255 Flash intensity 000 - 255 Red 7 000 - 255 Flash Duration 000 - 255 Green7...
  • Page 16 000 - 255 White section9 000 - 255 White section 10 000 - 255 White section 11 000 - 255 White section 12 000 - 255 Red13 000 - 255 Green13 000 - 255 Blue13 000 - 255 Red 14 000 - 255 Green14 000 - 255...
  • Page 17 DMX control mode 000 - 255 Blue21 000 - 255 Red 22 000 - 255 Green22 3 CHANNELS 000 - 255 Blue22 Channel Value Function 000 - 255 Red 23 000 - 255 Flash intensity 000 - 255 Green23 000 - 255 Flash Duration 000 - 255 Blue23...
  • Page 18: Dmx-512 Addressing With Id Address

    DMX-512 addressing with ID address 1. Follow instructions 1 for DMX 512 addressing. 2. Activate ID addressing in each fixture by setting panel function “ID ON/OFF” to ON. “Settings” to “ID ON/OFF” to “ON” For every DMX 512 starting address the user can set 66 separate ID addresses.
  • Page 19 DMX MODE-In this menu,you can connect several pieces of lights with DMX cable and control them with the control console. Programme Menu Press ”ENTER” and then press “UP” or “DOWN” to ”Address” or “DMX Channel” and press “ENTER”. 1) “XXX” will be showed in “Address”, "XXX” means the Address 001-512. You can press “UP” or “DOWN”to select the address you desired.
  • Page 20 INFORMATION-In this menu, you can learn about the information of RDM, software and hardware of the light. 1.Press “ENTER” and then press “UP” or “DOWN” to “INFORMATION”. 2.Press “ENTER” and you can see 3 items as below: 1) RDM - It shows RDM information. 2) Hardware - It shows the Hardware information.
  • Page 21 Features Mounting ● Light Source: 360pcs white led,192pcs RGB 5050 1W LED When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit ● Beam angle: 90° must be secured with a secondary safety attach-ment, e.g.
  • Page 22 CABLE CONNECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the other end. DMX connector configuration GROUND caution:Do not allow contact between the ground and the fixture’s chassis ground. Grounding the ground can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify positive pole and to make sure the pins are not grounded or shorted to the shield or each other.
  • Page 23 Mechanical Specification RDM---Remote Device Management RDM is a wild version of the DMX512-A protocol, allowing dimming stations and other control devices to be discovered through a DMX512 network, and then configuring, status monitoring, and managing intermediate and line end devices. It allows two-way communication between the lighting device or system controller and the connected RDM compatible device through the standard DMX.
  • Page 24 IMPORTER B&K LUMITEC ZI – 2 Rue Alfred Kastler – 67850 Herrlisheim – France www.bklumitec.com...