4. Drill two
" (3 mm) holes that correspond to the bracket
holes of the determined mounting method. See below.
Floor Mounting
A. #12 x 1 " screws
B. Anti-tip bracket
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
A
B

Electrical Connection - U.S.A. Only

Wall Mounting
A
A. #12 x 1 " screws
B. Anti-tip bracket
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1 " screws provided.
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
B
7