Required Equipment

Refrigeration Gauges rated for A2L Refrigerants with temp scales for R-32 refrigerant.
Gauge Manifold (Right handed threads).
A2L compatible Vacuum Gauge capable of 300 microns or less.
Nitrogen regulator for purging and testing, rated to 800 psi. (Capable of low psi flow)
Pipe tubing cutter.
Refrigerant recovery cylinder. (Flammable A2L label)
Ventilation fan.
Class ABC fire extinguisher.
Process Tube adapter kit
Recovery access tool.
Purge hose fittings
Pinch off and opening tools
ABC Fire Extinguisher
Guage Manifold
Process tube adapter kit
27
80
R-32 SEALED SYSTEM REPAIR
Recovery Machine
Recovery access tool
Purge hose fittings
Vaccum Pump
Nitrogen Regulator
Nitrogen
Vaccum Guage
Pinch off and opening tools