Required Equipment
Refrigeration Gauges rated for A2L Refrigerants with temp scales for R-32 refrigerant.
•
Gauge Manifold (Right handed threads).
•
A2L compatible Vacuum Gauge capable of 300 microns or less.
•
•
Nitrogen regulator for purging and testing, rated to 800 psi. (Capable of low psi flow)
•
Pipe tubing cutter.
•
Refrigerant recovery cylinder. (Flammable A2L label)
•
Ventilation fan.
Class ABC fire extinguisher.
•
Process Tube adapter kit
•
•
Recovery access tool.
•
Purge hose fittings
•
Pinch off and opening tools
ABC Fire Extinguisher
Guage Manifold
Process tube adapter kit
27
80
R-32 SEALED SYSTEM REPAIR
Recovery Machine
Recovery access tool
Purge hose fittings
Vaccum Pump
Nitrogen Regulator
Nitrogen
Vaccum Guage
Pinch off and opening tools