About Your Appliance & Installation Requirements; Appliance Specifications; Clearances; Recommended Operating Conditions - True TAC-14GS-HC-LD Installation Manual

Table of Contents

Advertisement

About Your Appliance & Installation Requirements
About Your Appliance & Installation Requirements
USER ACTION!
TRUE is not responsible for damage incurred during
shipment. Always carefully inspect for freight damage
before receiving and installing your appliance. If
there is damage, note all damage on the delivery
receipt, immediately file a claim with the delivery
freight carrier, and contact TRUE.
Do not install the
appliance or put it in service.
Thank you for choosing TRUE Manufacturing to meet your
refrigeration needs. TRUE highly recommends a qualified
technician and electrician install your appliance to ensure correct
installation. The cost of professional installation is money well
spent. Only qualified technicians should install and service the
appliance.
For assistance finding a qualified technician, please visit our Service
Company Locator at
truemfg.com/support/service-locator.
is solely the appliance manufacturer and is not responsible for
installation.
The appliance owner is responsible for proper installation and
maintaining the appliance as described in this document. Routine
care and maintenance procedures are not covered by TRUE's
warranty.

Appliance Specifications

Some things to know about your appliance are as follows:
• Appliance tested for IEC to ISO Climate Class 8 [75°F (24°C)
temperature, 55% relative humidity].
• For proper operation, ambient temperatures shall not be
less than 60°F (15.5°C) and no greater than 75°F (24°C) or as
indicated on the serial label.
• Appliance is not for the storage and/or display of potentially
hazardous foods when the temperature control is set above
41˚F (5˚C).
• Appliance is not suitable for outdoor use, unless otherwise
stated on the serial label.
• Appliance is not suitable for an area where a pressure washer
or hose may be used.
Page 8 of 36
AIR CURTAIN
• Always plug the appliance into its own individual dedicated
electrical circuit!
• DO NOT use extension cords or adapter plugs.
• Before connecting your appliance to the power supply,
verify the incoming voltage (±5%) and the amps match the
operation ratings on the appliance's serial label. Correct
improper incoming voltage or amps immediately. Serial label
location varies by model.
• Before connecting your appliance to the power supply, verify
the power supply is correctly grounded. If the power supply
is not grounded, correct immediately.
• Ensure the installation location will provide adequate
clearances and sufficient airflow for the appliance.
See "Clearances" (pg. 8).
• Read and follow all warnings and maintenance instructions.
Failure to do so may result in damage and void the warranty
TRUE
on your appliance.

Clearances

NOTICE!
Warranty is void if ventilation is insufficient.
Be sure your appliance has the required surrounding
clearances for ventilation purposes. Keep all
ventilation openings in the appliance enclosure or
structure housing the appliance clear of obstruction.
MODEL
TOP
SIDES
TAC
8" (203.2 mm)
0" (0 mm)
12/13/2023
P#975542
truemfg.com
About Your Appliance & Installation Requirements (cont.)

Recommended Operating Conditions

• Do not place in direct sunlight.
• No HVAC supply or return air vents pushing air into or pulling
air out of the appliance.
• No ceiling fans.
• No doorways.
• Make sure appliance is level from front-to-back and
side-to-side.
NOTICE ›
Check for correct clearance in back of and above
the appliance. A 3" (77 mm) clearance is required at the rear
of the appliance and 8" (204 mm) clearance above
the appliance.
• Maximum ambient conditions 75°F (23.8°C) or as indicated
on the serial label, and 55% relative humidity.
• Place appliance in an area that will not have any air drafts.
• Excessive airflow around appliance can effect interior
appliance airflow (air-curtain).
BACK
3" (76.2 mm)
TEC_TM_086 | REV. C | EN
TEC_TM_086 | REV. C | EN
AIR CURTAIN
8 inches / 204 mm
≤ 75 º F
≤ 23 º C
≤ 55%
3 inches
77 mm
* Or as indicated on the serial label.
12/13/2023
truemfg.com
Page 9 of 36