INSTALLATION MANUAL – tcgg curved glass deli case TRUE MANUFACTURING CO., INC. 2001 East Terra Lane • O’Fallon, Missouri 63366-4434 (636)-240-2400 • FAX (636)-272-2408 • INT'L FAX (636)272-7546 • (800)-325-6152 Parts Department (800)-424-TRUE • Parts Department FAX# (636)-272-9471 Web: www.truemfg.com...
You have selected one of the finest commercial refrigeration units made. It is manufactured under strict quality controls with only the best quality materials available. Your TRUE cooler when properly maintained will give you many years of trouble-free service. WARNING: Use this appliance for its intended purpose as described in this Owner Manual.
NEMA plugs TRUE uses these types of plugs. If you do not have the right outlet have a certified electrician install the correct power source. NOTE: International plug configurations vary by voltage and country.
• Lamps must be replaced by identical lamps only. Before you start to install your TRUE unit, carefully inspect it for • Appliance tested according to the climate classes 5 and 7 freight damage. If damage is discovered, immediately file a claim with temperature and relative humidity.
PLUGGING INTO POWER SOURCE. INSUFFICIENT. Remove skid by unscrewing all base rail anchor brackets. Place Proper leveling of your TRUE cooler is critical to operating skid to the side. success (for non-mobile models). Effective condensate removal and door operation will be effected by leveling.
It may be necessary to seal the deli case to the floor for local sanitary codes or if the customer so desires. TRUE recommends either of the layer of tape on the floor prior to applying the sealant will protect following methods.
TRUE tcgg truemfg SETUP STANDARD ACCESSORIES STAINLESS STEEL SHELF INSTALLATION: NOTE: Shelf installation requires temporary removal of rear slide doors. A. Lift each door up and out oftrack (do not disconnect elastic tubing). Stretch elastic surgical tubing and set doors on each side of unit.
Page 9
TRUE tcgg truemfg INSTALLING BAKERY CASE SHELVES A. Lift each door up and out of track (do not disconnect elastic tubing). Stretch elastic surgical tubing and set doors on each side of unit. Remove brackets, lights, shelves, etc. from cabinet interior.
RECOMMENDATION - Before loading product we recommend to function several hours, completely cooling cabinet before you run your TRUE unit empty for two to three days. This allows changing the control setting. you to be sure electrical wiring and installation are correct and no Temperature Control Location and Settings.
TRUE tcgg truemfg MECHANICAL TEMPERATURE CONTROLS COIL SENSING An evaporator coil sensing temperature control ensures that the evaporator coil will remain clear of frost and ice by not allowing the compressor to restart until the coil temperature is above the freezing temperature.
Page 12
TRUE tcgg truemfg WHEN TO MAKE AN ADJUSTMENT TO A MECHANICAL TEMPERATURE CONTROL We advise to make a mechanical temperature control adjustment only for a high altitude location. HOW TO ADJUST A MECHANICAL TEMPERATURE CONTROL OPERATION INSTRUCTIONS: Scale Guide for Measuring...
Page 13
TRUE tcgg truemfg INSTRUCTIONS: DANFOSS TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE APPLICATIONS STEP 1 - Unplug cooler. STEP 2 - Remove the screws that secure the temperature control to the inset box. STEP 3 - To make these adjustments it may be necessary to remove the temperature control from the housing.
Page 15
Time initiated, time terminated. DEFROST TIME CLOCK OPERATION FOR UNITS WITH MECHANICAL CONTROL Your TRUE equipment contains a defrost system that is time initiated and time terminated. While TRUE requires a minimum three defrost RECOMMENDED DEFROST SETTINGS: periods not to exceed 60 minutes the procedure on this page should TRUE Manufacturing has factory set your defrost time clock to a be followed to customize your specific needs.
TRUE tcgg truemfg MAINTENANCE, CARE, CLEANING CLEANING THE CONDENSER COIL When using electrical appliances, basic safety precautions should be followed, including the following: TOOLS REQUIRED • Phillips Screwdriver • Air Tank or CO2 Tank • Stiff Bristle Brush • Vacuum Cleaner •...
Reconnect the electrical power to the unit. The Condenser looks like a group of vertical fins. You need to be able If you have any questions, please call TRUE Manufacturing at 636-240- to see through the condenser for the unit to function at maximum 2400 or 800-325-6152 and ask for the Service Department.
TRUE tcgg truemfg STAINLESS STEEL EQUIPMENT CARE 8 STEPS THAT CAN HELP PREVENT RUST ON AND CLEANING STAINLESS STEEL: CAUTION: Do not use any steel wool, abrasive or chlorine based USING THE CORRECT CLEANING TOOLS products to clean stainless steel surfaces.
TRUE tcgg truemfg GENERAL MAINTENANCE LIGHT BULB REPLACEMENT (INTERIOR LIGHTS) GENERAL MAINTENANCE WARNING: When replacing a light bulb make sure power to the unit is either turned off or unplugged. Be careful when removing the light bulb. Please be aware of your local ordinances in disposing old bulbs.
TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of three (3) years from the date of original installation or 39 months after shipment date from TRUE, whichever occurs first.