Media Sensor Calibration

This utility is used to calibrate the sensitivity of
the media sensor. The media sensor should be
calibrated whenever changing the label media
or after printer initialization. Please follow the
steps below to calibrate the media sensor.
Method 1:
1.
Make sure the ribbon and label media are
installed properly as described above.
2.
Press the
button to enter the
main menu.
3.
Press
and
select the "Setup" option and press
button to enter this option. And
enter the "Sensor"option.
4.
When enter this option, the sensor type in
the right side of ">" icon is the current
sensor setting. Press the
to select the sensor type, and
press the
button to calibrate
the media sensor.
Method 2:
1.
Make sure the ribbon and label media are
installed properly as described above.
2.
Turn off the printer power.
3.
Hold down the
button and
turn on the printer power.
4.
Do not release the buttons until printer
LCD shows "Calibrating...".

Printer Initialization

Printer Initialization will restore printer settings
to defaults. Please follow the steps below to
initialize the printer.
Method 1:
1.
Press the
button to enter the
main menu.
2.
Press
select the "Service" option and press
3.
And press
to scroll the cursor to "Initialization"
option and press
restore printer settings to defaults.
Method 2:
1.
Turn off the printer power.
2.
Press and hold
buttons to
turns on the printer's power.
3.
Do not release the buttons until printer
LCD shows "Initializing...".
Remove Used Ribbon
and
1.
Break the ribbon between ribbon guide
plate and the ribbon rewind spindle.
2.
Push the ribbon release button to release
the ribbon on the ribbon rewind spindle.
3.
Then, slide off the ribbon from ribbon
rewind spindle.
and
buttons to
button to enter this option.
and
buttons
button to
and
button at the same time then
© 2008 Wasp Technologies
Wasp 610/608

Quick Start Guide

Loading Ribbon

1.
Lift open printer right side cover. Push the
print head release lever to open the print
head mechanism.
2.
Install the ribbon onto the ribbon supply
spindle. Thread the ribbon through the ribbon
sensor slot and then through the open space
in between print head and platen.
Platen
Print head
release lever
Ribbon Supply
Spindle
Print head

Advertisement

loading

Summary of Contents for Wasp WPL608

  • Page 1: Media Sensor Calibration

    Push the ribbon release button to release the ribbon on the ribbon rewind spindle. Then, slide off the ribbon from ribbon rewind spindle. © 2008 Wasp Technologies Wasp 610/608 Quick Start Guide Loading Ribbon Lift open printer right side cover. Push the print head release lever to open the print head mechanism.
  • Page 2: Loading Media

    Print head mechanism Loading path for ribbon Loading Media Lift open printer right side cover. Push the print head release lever to open the print head mechanism. Print head release lever Move the label roll guard horizontally to the end of label spindle then flip down the label roll guard.