Available Modules - Siemens SIMATIC NET RUGGEDCOM RX1536 Equipment Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1536:
Table of Contents

Advertisement

Modules
4.2 Available Modules
Electrical hazard – risk of power failure
Power fluctuations or irregular shut downs may occur if the total power
consumption of all installed modules exceeds the power budget of the device.
Power Budget
Total Power Budget for the Device
Power Budget for Line Modules (@ 9 W Used For the System)
Module Power Consumption
RUGGEDCOM APE1808
RUGGEDCOM APE1402
RUGGEDCOM APE1404
2-Port Fiber Optic (FG50 + SFPs)
6-Port Fiber Optic (6FX50)
WAN Cell (3G, LTE)
2-Port Copper (M12, RJ45)
4-Port Copper (M12, RJ45)
6-Port Copper (M12, RJ45)
WAN T1, E1
Serial (S01)
Example
A device with the following modules installed would exceed the power budget for
line modules (41.5 W):
RUGGEDCOM APE1808
2-Port Fiber Optic (FG50 + SFPs)
6-Port Copper (M12, RJ45)
4.2

Available Modules

A variety of modules are available for use with the RUGGEDCOM RX1536.
For more information, refer to the
support.industry.siemens.com/cs/us/en/view/109747072]" for the RUGGEDCOM
RX1536.
28
NOTICE
Module Type
Module
Power Consumption
12 W
10 W
10 W
7 W
7 W
7 W
4 W
5 W
5 W
3 W
3 W
2
2
1
Total Consumption 43 W
"RUGGEDCOM Modules Catalog [https://
Equipment Manual, 10/2023, C79000-G8976-1488-07
50 W
41.5 W
Quantity
Consumption
24 W
14 W
5 W
RUGGEDCOM RX1536

Advertisement