New Outdoor Unit Placement

CAUTION
In order to avoid injury, take proper precaution when lift-
ing heavy objects.
Remove existing outdoor unit prior to placement of new
outdoor unit. See Unit Dimensions on page 2 for sizing
mounting slab, platforms or supports. Refer to figure 4 for
mandatory installation clearance requirements.
POSITIONING CONSIDERATIONS
Consider the following when positioning the unit:
S
Some localities are adopting sound ordinances based
on the unit's sound level registered from the adjacent
property, not from the installation property. Install the
unit as far as possible from the property line.
S
When possible, do not install the unit directly outside
a window. Glass has a very high level of sound
transmission. For proper placement of unit in relation
to a window see the provided illustration in figure 5,
detail A.
PLACING UNIT ON SLAB
When installing unit at grade level, the top of the slab
should be high enough above grade so that water from
CLEARANCE ON ALL SIDES
MINIMUM CLEARANCE BETWEEN TWO UNITS
Roof Damage!
This system contains both refrigerant and oil. Some rubber roofing material may absorb oil and cause the rubber to swell
when it comes into contact with oil. The rubber will then bubble and could cause leaks. Protect the roof surface to avoid
exposure to refrigerant and oil during service and installation. Failure to follow this notice could result in damage to roof
surface.
INCHES (MILLIMETERS)
NOTES:
S
Service clearance of 30 inches (762 mm) must be
maintained on one of the sides adjacent to the
control panel
S
Clearance to one of the other three sides must be 36
inches (914mm).
S
Clearance to one of the remaining two sides may be
12 inches (305mm) and the final side may be 6
inches (152mm).
CONTROL PANEL ACCESS
LOCATION
24
(610)
Figure 4. Installation Clearances
NOTICE
higher ground will not collect around the unit. The slab
should have a slope tolerance as described in figure 5,
detail B.
NOTE
If necessary for stability, anchor unit to slab as
described in figure 5, detail D.
ELEVATING THE UNIT
Units are outfitted with elongated support feet as illustrated
in figure 5, detail C.
If additional elevation is necessary, raise the unit by
extending the height of the unit support feet. This may be
achieved by using a 2 inch (50.8mm) schedule 40 female
threaded adapter.
NOTE
Keep the height of extenders short enough to
ensure a sturdy installation. If it is necessary to extend
further, consider a different type of field−fabricated
framework that is sturdy enough for greater heights.
ROOF MOUNTING
Install the unit a minimum of 6 inches (152 mm) above the
roof surface to avoid ice build−up around the unit. Locate
the unit above a load bearing wall or area of the roof that
can adequately support the unit. Consult local codes for
rooftop applications. See figure 5, detail F for other roof top
mounting considerations.
Page 7
MINIMUM CLEARANCE
ABOVE UNIT
48 (1219)
XP13 SERIES