Configuration Option Menu (Continued)
OM-240 712 Page 24
AUTO
PULS
ARC.L
PULS
WFS
INFO
EXIT
Pulsed MIG Manual/Auto Control
This option sets the Pulsed MIG control as
manual (PULS MAN) or Auto (PULS AUTO)
operation. When set to manual operation, the
arc length setting on power source and wire
speed setting on wire feeder need to be ad-
justed independently to achieve the desired
arc length. When set to Auto operation, once
arc length is determined it is not necessary to
change the arc length value with changes in
wirefeed speed.
The AlumaPower 350 MPa and synergic
feeders allow single knob control of the arc.
As wirefeed speed is increased or decreased,
the pulse parameters increase or decrease
matching the power output to the wire speed.
.
Pulsed MIG Adjustment
This option allows adjusting the Pulsed MIG
process in units of Arc Length (PULS ARC.L)
or preset voltage (PULS VOLT).
IPM
Wire Feed Speed And Wire Diameter Units
WFS IPM:
WFS is displayed in inches per minute
Diameter is displayed in inches
WFS MPM:
WFS is displayed in meters per minute
Diameter is displayed in millimeters
Revision Information
NO
This option identifies the unit's weld library
(INFO LIB) and firmware revision (INFO
REV).
Press the Setup Button while the unit is dis-
playing INFO LIB to identify the unit's weld li-
brary.
Press the Setup Button while the unit is dis-
playing INFO REV to identify the unit's firm-
ware revision.
Pressing the Setup Button while the unit is dis-
playing INFO NO will move to the next config-
uration option.
Exit Configuration Option Menu
NO
Press the Setup Button while the unit is dis-
playing EXIT NO to return to the first configu-
ration option. Press the Setup Button while the
unit is displaying EXIT YES to exit the Config-
uration Option Menu.
.
Auto Operation will only work with syner-
gic wire feeders. All other wire feeders will
only operate as manual control. Even
when Auto is displayed, operation will be
manual when any other feeder is connec-
ted. See product literature for a list of
compatible synergic wire feeders.
The Configuration Option Menu can be
exited at any time by turning the unit off.
Only if the unit is turned off after EXIT NO
is displayed will configuration option
changes be saved.