Daikin Altherma EHVH/X16S18+26CA Installer's Reference Manual page 41

Low temperature split
Table of Contents

Advertisement

#
Code
[A.3.1.2.3]
[0-00]
Set weather-dependent heating:
[0-01]
T t
[0-02]
[0-03]
[0-01]
[0-00]
▪ T
(main)
▪ T
▪ [0-03]:
temperature.
−10°C)
▪ [0-02]:
temperature.
15°C)
▪ [0-01]:
temperature
temperature equals or drops below
the low ambient temperature.
Between minimum and maximum
leaving
25°C~depending on outdoor unit
(default: 45°C).
Note: This value should be higher
than [0-00] as for low outdoor
temperatures
required.
▪ [0-00]:
temperature
temperature equals or rises above
the high ambient temperature.
Between minimum and maximum
leaving
25°C~depending on outdoor unit
(default: 35°C).
Note: This value should be lower
than [0-01] as for high outdoor
temperatures less warm water is
required.
ERHQ011~016BA + ERLQ011~016CA + EHVH/X16S18+26CA
Daikin Altherma - Low Temperature Split
4P313777-1C – 2012.11
Description
[0-03]
[0-02]
: Target leaving water temperature
t
: Outdoor temperature
a
Low
outdoor
ambient
−20°C~5°C
(default:
High
outdoor
ambient
10°C~20°C
(default:
Desired
leaving
water
when
the
outdoor
water
temperature
warmer
water
Desired
leaving
water
when
the
outdoor
water
temperature
#
Code
[A.3.1.2.4]
[0-04]
[0-05]
[0-06]
[0-07]
T a
is
Leaving water temperature: Delta T emitter
Temperature difference for entering and leaving water. The unit is
designed to support under floor loops operation. The recommended
leaving water temperature (set by the user interface) for under floor
loops is 35°C. In such case, the unit will be controlled to realize a
temperature difference of 5°C which means that the entering water
to the unit is around 30°C. Depending on the installed application
(radiators, heat pump convector, under floor loops) or situation, it
can be possible to change the difference between entering and
leaving water temperature. Note that the pump will regulate its flow
to keep the Δt.
#
Code
[A.3.1.3.1]
[9-09]
[A.3.1.3.2]
[9-0A]
8 Configuration
Description
Set weather-dependent cooling:
T t
[0-05]
[0-04]
[0-07]
[0-06]
▪ T
: Target leaving water temperature
t
(main)
▪ T
: Outdoor temperature
a
▪ [0-07]:
Low
outdoor
temperature.
10°C~25°C
20°C)
▪ [0-06]:
High
outdoor
temperature.
25°C~43°C
35°C)
▪ [0-05]:
Desired
leaving
temperature
when
the
temperature equals or drops below
the low ambient temperature.
Between minimum and maximum
leaving water temperature 5°C~22°C
(default: 12°C).
Note: This value should be higher
than [1-09] as for low outdoor
temperatures
less
cold
suffices.
▪ [0-04]:
Desired
leaving
temperature
when
the
temperature equals or rises above
the high ambient temperature.
Between minimum and maximum
leaving water temperature 5°C~22°C
(default: 8°C).
Note: This value should be lower
than [1-08] as for high outdoor
temperatures
colder
water
required.
Description
Heating: required temperature
difference between entering and
leaving water. Range: 3~10°C (in steps
of 1°C; default value: 5°C).
Cooling: required temperature
difference between entering and
leaving water. Range: 3~10°C (in steps
of 1°C; default value: 5°C).
Installer reference guide
T a
ambient
(default:
ambient
(default:
water
outdoor
water
water
outdoor
is
41