DUAL PISTON WIRING DIAGRAM

RED
GREEN
LDM
LDCAM
LOWER DRIVE
VDM
HCAM
UPPER DRIVE
BVCAM
22 • 3200 NXT
FE12
OPTIONAL MOTOR/PUMP ON DURING REGENERATION
OR CPO DEVICE ON DURING SERVICE(N.O.OUTPUT)
SWITCHED HOT
M 1
OPTIONAL INTERLOCK
SWITCH (N.O.)
OPTIONAL REMOTE
SIGNAL START
SWITCH (N.O.)
AUX
F1
WHITE
BLACK
UPPER DRIVE
SCAM
T1 - 24V TRANSFORMER
VDM- VALVE DRIVE MOTOR
SW1- VALVE HOMING SWITCH
SW2- VALVE STEP SWITCH
SW3 - BRINE CAM SWITCH
HCAM- VALVE HOMING CAM
SCAM- VALVE STEP CAM
BVCAM - BRINE VALVE CAM
FM - FLOW METER (OPTIONAL)
M1 - MOTOR OR PUMP (OPTIONAL)
S1 - SOLENOID VALVE (OPTIONAL)
NOTE:
1. TRANSFORMER FUSE - 5A 250V SLOW-BLOW P/N 41143
2. VALVE SHOWN IN SERVICE
NEUTRAL
24VAC/3A MAX. RESISTIVE
30VDC/3A MAX. RESISTIVE
UNSWITCHED HOT
*ONLY AVAILABLE ON 3200NXT AND XT
-CLOSED CONTACT INITIATES REGENERATION IF OPTION ENABLED
-INPUT SIDE PULLED UP TO 32 VDC
CAN2
CAN1
OPTIONAL FLOW METER
- NOT REQUIRED FOR TIME CLOCK OR REMOTE SIGNAL START
REGENERATION APPLICATIONS
GRN/YEL
24V AC
METER
BACKPLATE
GROUND SCREW
FM
*ONLY AVAILABLE ON 3200NXT AND 3214NXT
-CLOSED CONTACT PREVENTS REGENERATION
-INPUT SIDE PULLED UP TO 32 VDC