29.2. Alarm Output
Main Menu/Alarm Setting/Alarm Output
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Alarm Setting
Alarm Enable
Alarm Input
Alarm Output
MD Dwell Time
Alarm Output
Setting 1
1 2 MD AUX
Setting 2
1 2 MD AUX
Timer 1
OFF
Timer 2
OFF
OUT Off 1
OUT Off 2
Notes
• Connecting the power connector and GND incorrectly to the NC/NO and COM ports may
cause a short circuit and fire, damaging the camera.
• The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera's
lifespan and damage it.
Setting 1,2 :
Enables selecting an Alarm Output method.
- 1, 2, Motion, and Support Device indicate alarm input
ports, Motion Detection, and support device input. A total of
4 alarms, Motion Detection, and support devices can be set
up to output alarms. 1 alarm output port can be used for
more than 2 alarm inputs and Motion Detection.
Timer 1,2 :
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 minutes
upon the alarm occurrence.
OFF
- Momentary : Retains an alarm output only until the alarm is
✽ The Alarm Output is equipped with a relay circuit. The
operation of the alarm output port is as shown in the
OFF
diagram below. (Normally Opened)
Alarm Out OFF
SPEED DOME CAMERA
canceled.
NO
COM
NC
83
User Guide
NO
COM
NC
Alarm Out ON