Connecting the refrigerator
➤ Connect the refrigerator securely by hand to the gas supply (fig. h, page 10):
A
NOTICE!
Always use a backup wrench (size 17 mm) when connecting the gas
supply line to the refrigerator's gas inlet fitting.
No. in
fig. h, page 10
1
2
3
4
➤ Have a leak test and a flame test performed by an authorized specialist after pro-
fessional installation.
Ensure you are issued with a certificate of inspection and hand this certificate to
the end user for safekeeping.
6.2
Connecting to DC and AC
A
NOTICE!
The electrical installation and repairs may only be performed by a spe-
cialist in accordance with the applicable regulations and standards.
22
Description
Screw M4 (Torx TX20)
Tightening torque: 2 Nm
Refrigerator gas connection
M14 x 1.5 (d = 8 mm/ISO8434 (DIN2353))
Gas pipe with ring coupling (size 17)
Tightening torque: 25 Nm
Backup wrench (17 mm)
RMD10