Advertisement

Quick Links

NADDOD S3600 Series Ethernet Switches
Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for NADDOD S3600 Series

  • Page 1 NADDOD S3600 Series Ethernet Switches Installation Guide...
  • Page 2 NADDOD, and may also contact the headquarters of the Company directly. Where readers face any problem about the products of NADDOD , or intend to learn more about other relevant products of the Company, they may contact us by the following ways: Website of the Company: http://www.naddod.com/...
  • Page 3 Overview This document presents product introduction, installation guide, startup after power on, maintenance and troubleshooting of NADDOD S3600 Series Layer 3 Ethernet Switches (hereinafter referred to as S3600 Series). Product Version The product versions corresponding to this document are as follows.
  • Page 4 S3600 Series Installation Guide Foreword General Format Stipulations Format Description Song The main body is in Song. Gothic Level 1 title, Level 2 title, Level 3 title and Block are in Gothic. Regular Warnings and hints are in Regular. Lucida Console Lucida Console format indicates screen output.
  • Page 5: Table Of Contents

    1.1 Product Model Description ..........................6 1.2 S3600 Series Front Panel Description .......................7 1.2.1 S3600-24T24S4X ....................错误!未定义书签。 1.2.2 S3600-48S4X ......................错误!未定义书签。 1.3 S3600 Series Back Panel Description ....................... 8 1.3.1 S3600-24T24S4X ....................错误!未定义书签。 1.3.2 S3600-48S4X ......................错误!未定义书签。 1.4 S3600 Series Port Description ...........................9 1.4.1 Service Port ..............................9...
  • Page 6 S3600 Series Installation Guide Contents 3.2 Setting up Terminal Parameters (Windows Hyperterminal) ................15 3.3 Setting up Port Parameters (SecureCRT) ......................17 3.4 Power on of Switch ............................19 4 Technical Data ..........................20 4.1 Overall Parameters ............................20 5 Switches System Software Loading .....................21 6 Switches Operating System Upgrade ..................23...
  • Page 7: Product Introduction

    NADDOD S3600 Series Switches have enhanced Layer 3 functions, large tablebody, and VXLAN, support IPV4 and IPV6 management and forwarding, and are of rich security features. NADDOD S3600 Series Switches are flexible for networking and easy to maintain, and are widely applied for aggregation or access of large and medium-scaled campus network or data center, and core of small campus network.
  • Page 8: S3600 Series Front Panel Description

    S3600 Series Installation Guide Product Introduction 1.2 S3600 Series Front Panel Description 1.2.1 S3600-24T24S4X Figure 1-1 Schematic Diagram of S3600-24T24S4X Front Panel (2): 10/100/1000BASE-T self-adapting Ethernet port status (1): 10/100/1000BASE-T self-adapting Ethernet port indicator (3): 1G SFP+ optical interface (4): SFP port status indicator...
  • Page 9: S3600 Series Back Panel Description

    S3600 Series Installation Guide Product Introduction 1.3 S3600 Series Back Panel Description 1.3.1 S3600-24T24S4X Figure 1-3 Schematic Diagram of S3600-24T24S4X Back Panel (1): Grounding screw (2): Expansion slot 1 (3): Expansion slot 2 (4): Pluggable fan 1 (5): Pluggable fan 2...
  • Page 10: S3600 Series Port Description

    S3600 Series Installation Guide Product Introduction 1.4 S3600 Series Port Description 1.4.1 Service Port Table 1-2 shows service ports of S3600 Series. Table 1-2 Service Ports of S3600 Series Port type Count Description Uplink S3600-24T24S4X The supported optical module types include: port 10G SFP+ optical interface;...
  • Page 11: Management Port

    S3600 Series Installation Guide Product Introduction Table 1-4 Properties of 1G SFP Interface Property Description Connector type Optical Depend on the selected SFP module interface properties Operating mode Full duplex Standard IEEE 802.3 1G Ethernet Electrical Interface Table 1-5 shows properties of the 10/100/1000M Ethernet electrical interface.
  • Page 12 Ethernet Management Port S3600 series switches integrate out-of-band management Ethernet interface, and the interface is 1000Base-TX or 100Base-T. It is recommended to use the attached cables, which are generally used to connect computer for program loading and debugging of system or connect remote network management station for remote management of system.
  • Page 13: S3600 Series Indicator Description

    NADDOD doesn’t promise that all USB devices from various manufacturers can work normally on S3600 Series Switches. Malfunction of any USB device should not be attributed to switch fault. In such case, please try USB devices from different manufacturers.
  • Page 14: Power Indicator

    S3600 Series Installation Guide Product Introduction 1.5.2 Power Indicator The running state of S3600 power modules can be judged via the pluggable power module status indicator on the front panel, as show in Table 1-9. Table 1-9 Pluggable Power Module Status Indicator Description...
  • Page 15: Sfp Port Status Indicator

    S3600 Series Installation Guide Product Introduction Indicator name Status Description The port is not linked up 1.5.5 SFP Port Status Indicator Table 1-12 SFP Port Status Indicator Description Indicator name Status Description 1-48 Yellow Flash The 1G port is sending or receiving data...
  • Page 16: Installation Guide

    2.1.2 Pre-installation Check To ensure a normal work environment of switches, S3600 Series Switches have the following requirements for the operational site: Be sure to leave space at the air intake vent and ventilation opening of switches to ...
  • Page 17 S3600 Series Installation Guide Installation Guide Be sure to ground the chassis and workbench properly.  To guarantee long-term steady operation of the switches, the installation site also must meet the following requirements: Temperature and humidity To guarantee normal operation and the service life of switches, the machine room must maintain a certain temperature and humidity.
  • Page 18: Installation Tools

    S3600 Series Installation Guide Installation Guide Table 2-3 Harmful Gas Limit of Machine Room Max (mg/m3) 0.006 0.05 0.01 Anti-interference Switches in operation might be subject to interference outside the system, which affects the equipment via capacitive coupling, inductive coupling, electromagnetic radiation, common impedance (including grounding system) coupling and transmission mode of wires (power line, signal line and output line, etc.).
  • Page 19: Installation

    NOTE The switches of this series come without installation tools, which must be prepared by users. 2.2 Installation S3600 series switches can be installed in two ways: Installing by fixing the front suspension loop and chassis tray.  Installing on the table.
  • Page 20 S3600 Series Installation Guide Installation Guide Figure 2-2 Step 3: Take out screws (packaged along with the front suspension loop), and install one end of the front suspension loop onto switch, as shown in Figure 2-3 Figure 2-3 Schematic Diagram of Front Suspension Loop Installation...
  • Page 21: Installing Switch On The Table

    S3600 Series Installation Guide Installation Guide Figure 2-4 Schematic Diagram after Installing Switch onto Chassis (with Tray) 2.2.3 Installing Switch on the Table Most users have no 19-inch standard chassis. The common practice in such case is to place switch on a clean workbench. This is simple, and only the following matters must be kept in mind: The workbench must be stable and grounded properly.
  • Page 22: Installation And Disassembling Of Power Module

    Figure 2-5 Schematic Diagram of Foot Pad Installation 2.2.4 Installation and Disassembling of Power Module Installation Procedure The power module of S3600 series switches support hot plug, and the installation procedure is as below: Step 1: Wear anti-electrostatic wrist, and confirm the anti-electrostatic wrist is grounded properly.
  • Page 23: Ground Connection

    S3600 Series Installation Guide Installation Guide CAUTION S3600 series switches can be installed with two power modules for hot spare, so that switching to another power supply (without power interruption) can be realized in the case of one power supply failure.
  • Page 24: Initial Startup After Power On Of Switches

    S3600 Series Installation Guide Initial Startup after Power on of Switches Initial Startup after Power on of Switches 3.1 Building Configuration Environment and Connecting Cables Figure 3-1 Building Local Configuration Environment via Console Port Step 1 Connect the DB-9 hole plug of the provided cable to the serial port of a PC via which switch configuration will be made.
  • Page 25: Setting Up Terminal Parameters (Windows Hyperterminal)

    S3600 Series Installation Guide Initial Startup after Power on of Switches 3.2 Setting up Terminal Parameters (Windows Hyperterminal) Step 1 Boot PC, and run a terminal emulator on the PC (Windows system is provided with a hyperterminal); Step 2 Setting up terminal parameters (example of Windows XP Hyperterminal) The method is as follows: Go to the hyperterminal window by tapping “start ...
  • Page 26 S3600 Series Installation Guide Initial Startup after Power on of Switches Figure 3-3 Setting Port Connection After selecting serial port, click <OK> button, the parameter setting interface for serial connection will pop up, and set the parameters as follows: bps 115200, data bits 8, parity null, stop bits 1 and data flow control null.
  • Page 27: Setting Up Port Parameters (Securecrt)

    S3600 Series Installation Guide Initial Startup after Power on of Switches Figure 3-5 Setting of Terminal Emulation from the “Network Properties” Interface CAUTION Please use the attached DB-9 to RJ-45 cable to avoid incompatibility. 3.3 Setting up Port Parameters (SecureCRT) Step 1 Install SecureCRT software on PC;...
  • Page 28 S3600 Series Installation Guide Initial Startup after Power on of Switches Figure 3-7 Serial Protocol Settings Choose a serial number for PC (an example of COM4). Figure 3-8 Serial Parameter Settings (Serial Number Selection) Set Baud rate as 115200, data bits as 8, parity as null, stop bits as 1, and flow control as XON/XOFF, and click Connect button.
  • Page 29: Power On Of Switch

    S3600 Series Installation Guide Initial Startup after Power on of Switches Figure 3-9 Serial Port Display Window CAUTION Please use the attached DB-9 to RJ-45 cable to avoid incompatibility. 3.4 Power on of Switch After power on of switch, the terminal shows device self-checking information, and the system turns to cmd (such as switch#) after self-checking is completed.
  • Page 30: Technical Data

    S3600 Series Installation Guide Technical Data Technical Data This chapter presents overall indicators, system indicators, single-board indicators and performance indicators of S3600 series products, as follows: Overall Parameters  4.1 Overall Parameters Table 4-1 shows overall parameters of S3600 products.
  • Page 31: Switches System Software Loading

    S3600 Series Installation Guide Switches System Software Loading Switches System Software Loading The conventional switches software loading mode is serial port loading, which is slow, time-consuming, incapable of remote loading, and inconvenient to operation. To solve these problems, a TFTP module is introduced for switches, which enables software loading and file downloading via Ethernet port.
  • Page 32 S3600 Series Installation Guide Switches System Software Loading Use the command reenv to restore environment variables of switch to default. Step 3: Run TFTP Server program on the PC serving as server, and set the catalogue for files to be loaded, assuming the uBoot file to upgraded as u_boot_v1.0.bin.
  • Page 33: Switches Operating System Upgrade

    S3600 Series Installation Guide Switches Operating System Upgrade Switches Operating System Upgrade S3600 series switches can be upgraded via operating system software rather than replacing hardware to add new features and enhance system performance. Figure 6-1 Upgrading Operating System Step 1: Copy system software to be upgraded to switch In privilege mode of switch, use the command copy to copy the software image on TFTP server to the folder boot of switch Flash.
  • Page 34 S3600 Series Installation Guide Switches Operating System Upgrade Switch(config)# boot system flash:/boot/SwitchOS-ma-v3.1.12.it.r.bin Step 3: View the software Image loaded after reboot of the switch next time After setting the Image for use by the switch after reboot next time, you can use the command show to view whether the setting is correct.
  • Page 35: Maintenance And Troubleshooting

    S3600 Series Installation Guide Maintenance and Troubleshooting Maintenance and Troubleshooting 7.1 Troubleshooting of Load Failure In the case of load failure, the system will run the original version. In this case, users ought to check connection of physical ports first. If port connection is not made properly, reconnect the ports correctly, and conduct reloading.
  • Page 36: Troubleshooting Of Power-Supply System Failure

    S3600 Series Installation Guide Maintenance and Troubleshooting 7.3 Troubleshooting of Power-supply System Failure You can judge whether the power-supply system of switch goes wrong via the PWR indicator on the front panel: PWR indicator being always on means normal operation; please run checks if the PWR indicator is off: Whether the power cord of switch is connected correctly.

This manual is also suitable for:

S3600-24t24s4xS3600-48s4x

Table of Contents