Advertisement

Quick Links

NADDOD S3200P/S2200 Series Ethernet
Switches Installation Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for NADDOD S2200 Series

  • Page 1 NADDOD S3200P/S2200 Series Ethernet Switches Installation Instruction Manual...
  • Page 2 NADDOD, and may also contact the headquarters of the Company directly. Where readers face any problem about the products of NADDOD , or intend to learn more about other relevant products of the Company, they may contact us by the following ways: Website of the Company: http://www.naddod.com/...
  • Page 3 Foreword Overview This document presents product introduction, installation guide, startup after power on, maintenance and troubleshooting of S3200P & S2200 Series full Gigabyte Ethernet Switches (hereinafter referred to as S3200P & S2200 Series). Product Version The product versions corresponding to this document are as follows.
  • Page 4 S3200P&S2200 Series Installation Guide Product Introduction Symbol Description Text marked with this symbol may help you address certain issues or save your time. General Format Stipulations Format Description Song The main body is in Song. Gothic Level 1 title, Level 2 title, Level 3 title and Block are in Gothic.
  • Page 5: Table Of Contents

    S3200P&S2200 Series Installation Guide Product Introduction Contents 1 Product Introduction ........................vi 1.1 Product Model Description ..........................vi 1.2 S3200P&S2200 Series Front Panel Description ..................... vii 1.2.1 S3200P-24T4X ............................vii 1.2.2 S3200P-48T4X ............................. viii 1.2.3 S2200-24T4X ............................viii 1.2.4 S2200-48T4X ............................ix 1.3 S3200P Series Back Panel Description ......................ix 1.3.1 S3200P-24T4X ............................ix...
  • Page 6 S3200P&S2200 Series Installation Guide Product Introduction 2.3 Ground Connection ............................24 3 Initial Startup after Power on of Switches ..................26 3.1 Building Configuration Environment and Connecting Cables ................26 3.2 Setting up Terminal Parameters (Windows Hyperterminal) ................27 3.3 Setting up Port Parameters (SecureCRT) ......................29 3.4 Power on of Switch ............................
  • Page 7: Product Introduction

    Product Introduction S2200 & S3200P Series Ethernet Switches are new generation high-performance Gigabyte Ethernet Switches launched by Naddod Networking, which provide rich port forms such as 10/100/1000Base-T self-adapting Ethernet port and 10G SFP+ optical interface, support pluggable dual power supply, and are widely applied in network environment of high-performance, high reliability, high port density and convenience in installation to address users’...
  • Page 8: S3200P&S2200 Series Front Panel Description

    48 10/100/1000 Base-T ports, including 4 10G SFP+  ports Built-in fixed single power supply  1.2 S3200P&S2200 Series Front Panel Description 1.2.1 S3200P-24T4X Figure 1-1 Schematic Diagram of S3200P-24T4X Front Panel (2): 10/100/1000BASE-T self-adapting Ethernet port status (1): 10/100/1000BASE-T self-adapting Ethernet port...
  • Page 9: S3200P-48T4X

    S3200P&S2200 Series Installation Guide Product Introduction 1.2.2 S3200P-48T4X Figure 1-2 Schematic Diagram of S3200P-48T4X Front Panel (2): 10/100/1000BASE-T self-adapting Ethernet port status (1): 10/100/1000BASE-T self-adapting Ethernet port indicator (3): USB port (4): Ethernet management port (5): CONSOLE port (6): System status indicator (SYS)
  • Page 10: S2200-48T4X

    S3200P&S2200 Series Installation Guide Product Introduction 1.2.4 S2200-48T4X Figure 1-4 Schematic Diagram of S2200-48T4X Front Panel (1): 10/100/1000BASE-T self-adapting Ethernet port (2): 10/100/1000BASE-T Ethernet port status indicator (3): Reset button (4): System status indicator (SYS) (5): Power indicator (PWR) (6): 10G SFP+ port...
  • Page 11: S3200P-48T4X

    S3200P&S2200 Series Installation Guide Product Introduction 1.3.2 S3200P-48T4X Figure 1-6 Schematic Diagram of S3200P-48T4X Back Panel (1): Grounding screw (2): Cooling fan 1 (4): Pluggable power module 1 (3): Cooling fan 2 (PSU1) (4): Pluggable power module 2 (PSU2) NADDOD Pte. Ltd.
  • Page 12: S2200-24T4X

    Figure 1-8 Schematic Diagram of S2200-48T4X Back Panel (1): Grounding screw (2): AC power port 1.4 S3200P&S2200 Series Port Description 1.4.1 Service Port Table 1-2 shows service ports of S3200P&S2200 Series. Table 1-2 Service Ports of S3200P Series Port type Count Description...
  • Page 13 S3200P&S2200 Series Installation Guide Product Introduction Port type Count Description S3200P-48T4X The supported optical module types include: 10G SFP+ optical interface; the supported SFP+  optical module type: 10GBASE-X 1G SFP+ optical interface; the supported SFP+  optical module type: 1000BASE-X...
  • Page 14 S3200P&S2200 Series Installation Guide Product Introduction 10G SFP+ Optical Interface Table 1-3 shows properties of the 10G SFP+ optical interface. Table 1-3 Properties of 10G SFP+ Optical Interface Property Description Connector type Optical Depend on the selected SFP+ optical module...
  • Page 15: Management Port

    1.4.2 Management Port Console Port The front panel of S3200P&S2200 Series Switches provides a serial CONSOLE port, of which the properties are shown in Table 1-6. Table 1-6 Properties of CONSOLE Port...
  • Page 16: S3200P&S2200 Series Indicator Description

    Switch is power off or system booting fails 1.5.2 Power Indicator The back panel of S3200P Series Switches provides two pluggable power module sockets. S2200 Series Switches support one power supply. The running state of power modules can be NADDOD Pte. Ltd.
  • Page 17: Port Mode Indicator

    S3200P&S2200 Series Installation Guide Product Introduction judged via the pluggable power module status indicator on the front panel, as show in Table 1-9. Table 1-9 Pluggable Power Module Status Indicator Description Indicator Status Description name Green, always on Normal output of power module Fault or failure to power on of power module 1.5.3 Port Mode Indicator...
  • Page 18: 10/100/1000Base-T Self-Adapting Ethernet Port Status Indicator

    S3200P&S2200 Series Installation Guide Product Introduction 1.5.5 10/100/1000BASE-T Self-adapting Ethernet Port Status Indicator Combining port mode indicator with 10/100/1000BASE-T self-adapting Ethernet port allows to indicate detailed operating state of port from different aspects, as shown in Table 1-12. Table 1-12 Description of 10/100/1000BASE-T Self-adapting Ethernet Port Status Indicator...
  • Page 19: Installation Guide

    S3200P&S2200 Series Installation Guide Installation Guide Installation Guide 2.1 Preparation before Installation 2.1.1 Safety Warning To prevent personal injury caused by equipment trouble due to improper use, please keep in mind the following: The power cable must be unplugged before cleaning the switches. Don’t wipe the ...
  • Page 20 S3200P&S2200 Series Installation Guide Installation Guide Make sure that the chassis and workbench are provided with a good ventilation and  cooling system. Make sure that the chassis and workbench are sufficiently secure to support the weight of  switches plus the installation accessories.
  • Page 21 S3200P&S2200 Series Installation Guide Installation Guide Besides dust, switches room is also subject to strict requirements for the content of salt, acid and sulfide in the air. These harmful gases will accelerate corrosion of metals and the ageing of some parts. Measures must be taken to prevent harmful gases such as SO2, H2S, NH3 and Cl2 from intruding into the machine room.
  • Page 22: Installation Tools

    NOTE The switches of this series come without installation tools, which must be prepared by users. 2.2 Installation S3200P&S2200 series switches can be installed in two ways: Installing via front suspension loop  Installing by fixing the front suspension loop and chassis tray.
  • Page 23 S3200P&S2200 Series Installation Guide Installation Guide Installation Steps Step 1 Inspect the stability of chassis. Step 2 Install suspension loops and fix with screws. Figure 2-1 . shows how to install suspension loops on one side. The installation of the other suspension loops is same.
  • Page 24: Installation And Disassembling Of Power Module

    S3200P&S2200 Series Installation Guide Installation Guide Figure 2-3 Step 5 Horizontally fix suspension loops onto the guide slots of the chassis to complete the installation, as shown in Figure 2-4. Figure 2-4 2.2.2 Installation and Disassembling of Power Module Installation Procedure...
  • Page 25: Ground Connection

    S3200P&S2200 Series Installation Guide Installation Guide hold the bottom of power module with another hand, and horizontally insert the power module along the power supply socket slide path until the power module is in place. Figure 2-5 Schematic Diagram of Power Module Installation...
  • Page 26 S3200P&S2200 Series Installation Guide Installation Guide Connect one end of the green-yellow protective grounding cable of switch to the grounding terminal of switch, and the other end to the wiring terminal on the grounding bar of machine room. NOTE The grounding wire of Ethernet switches must be connected and grounded with switch room.
  • Page 27: Initial Startup After Power On Of Switches

    S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches Initial Startup after Power on of Switches 3.1 Building Configuration Environment and Connecting Cables Figure 3-1 Building Local Configuration Environment via Console Port Step 1 Connect the USB plug of the provided cable to the serial port of a PC via which switch configuration will be made.
  • Page 28: Setting Up Terminal Parameters (Windows Hyperterminal)

    S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches 3.2 Setting up Terminal Parameters (Windows Hyperterminal) Step 1 Boot PC, and run a terminal emulator on the PC (Windows system is provided with a hyperterminal); Step 2 Setting up terminal parameters (example of Windows XP Hyperterminal) The method is as follows: Go to the hyperterminal window by tapping “start ...
  • Page 29 S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches Figure 3-3 Setting Port Connection After selecting serial port, click <OK> button, the parameter setting interface for serial connection will pop up, and set the parameters as follows: bps 115200, data bits 8, parity null, stop bits 1 and data flow control null.
  • Page 30: Setting Up Port Parameters (Securecrt)

    S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches Figure 3-5 Setting of Terminal Emulation from the “Network Properties” Interface CAUTION Please use the attached RJ-45 cable to avoid incompatibility. 3.3 Setting up Port Parameters (SecureCRT) Step 1 Install SecureCRT software on PC;...
  • Page 31 S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches Figure 3-7 Serial Protocol Settings Choose a serial number for PC (an example of COM4). Figure 3-8 Serial Parameter Settings (Serial Number Selection) Set Baud rate as 115200, data bits as 8, parity as null, stop bits as 1, and flow control as XON/XOFF, and click Connect button.
  • Page 32: Power On Of Switch

    S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches Figure 3-9 Serial Port Display Window CAUTION Please use the attached RJ-45 cable to avoid incompatibility. 3.4 Power on of Switch After power on of switch, the terminal shows device self-checking information, and the system turns to cmd (such as switch#) after self-checking is completed.
  • Page 33 S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches A. Click the arrow-pointed icon, enter the path where the file naddod-recovery-x86_64-n6100-48x8c-s-r0.iso is saved in the pop-up window, and select it to open. NADDOD Pte. Ltd.
  • Page 34 S3200P&S2200 Series Installation Guide Initial Startup after Power on of Switches A. Click Start button, choose DD Image Mode to write in in the pop-up dialog box, and click OK, until the startup disk making is completed. NADDOD Pte. Ltd.
  • Page 35: Technical Data

    S3200P&S2200 Series Installation Guide Technical Data Technical Data This chapter presents overall indicators, system indicators, single-board indicators and performance indicators of S3200P&S2200 series products, as follows: Overall Parameters  Laser Safety Class  Reliability Indicators  EMC Indicators  Safety Standards ...
  • Page 36: Laser Safety Class

     protection grade (kV) Ethernet electrical Indoor common mode 6 interface (kV) 4.2 Laser Safety Class The optical output power of the laser device of S3200P&S2200 series products shows the products are of laser safety class 1. NADDOD Pte. Ltd.
  • Page 37: Reliability Indicators

    Less than 2h MTBF 100000 hours 4.4 EMC Indicators S3200P&S2200 Series devices are designed in accordance with ETS300 386 series and ETS 300127 suggestions formulated by ETSI, and have passed EMC-related tests (Electromagnetic Compatibility). 4.5 Safety Standards S3200P&S2200 series comply with the following safety standards: EN 60950 ...
  • Page 38: Storage Conditions

    ETSI (European Telecommunication Standards Institute) EN 300 019  4.6.1 Storage Conditions Climatic Circumstance The requirements for climatic circumstance for the storage of S3200P&S2200 series are as shown in Table 4-4. Table 4-4 Climatic Circumstance Requirements for Storage Item Range Atmospheric pressure (kPa) 86~106...
  • Page 39: Transport Environment

     4.6.3 Operating Environment Climatic Circumstance The requirements for climatic circumstance for the operation of S3200P&S2200 series are as shown in Table 4-6. Product temperature and humidity refer to numerical values measured 1.5m above the ground and 0.4m before the product.
  • Page 40: Standards And Protocols

    S3200P&S2200 Series Installation Guide Technical Data Table 4-6 Other Climatic Circumstance Requirements Item Range Atmospheric pressure (kPa) 86~106 Temperature (℃) 0~50 Relative humidity 10%~90% RH, no condensation Temperature alteration ratio ≤0.5 (℃/min) Solar radiation (W/s²) ≤700 Thermal radiation (W/s²) ≤600 Wind speed (m/s) ≤5...
  • Page 41 S3200P&S2200 Series Installation Guide Technical Data ITU-T Y.1731 OAM Functions and Mechanisms for Ethernet based networks  ITU-T G.8031 Ethernet linear protection switching  ITU-T G.8032 Ethernet ring protection switching  ITU-T G.8261 Timing and Synchronization Aspects in Packet Networks ...
  • Page 42: Install License

    S3200P&S2200 Series Installation Guide Install License Install License Place license under ftp server catalogue (similar to installing system software) Type in the following commands via the serial port: copy mgmt-if ftp://192.168.1.11/d8860b0009d5.lic flash:/d8860b0009d5.lic Type in the command reload after the execution of the command Copy is completed...
  • Page 43: Maintenance And Troubleshooting

    S3200P&S2200 Series Installation Guide Maintenance and Troubleshooting Maintenance and Troubleshooting 6.1 Troubleshooting of Configuration System Failure After the switch is powered on, startup information will be shown on the configuration terminal if the system is normal; the configuration terminal may show no information or random codes if the configuration system goes wrong.

Table of Contents