NADDOD S4600 Series Ethernet Switches
Installation Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for NADDOD S4600 Series

  • Page 1 NADDOD S4600 Series Ethernet Switches Installation Instruction Manual...
  • Page 2 NADDOD, and may also contact the headquarters of the Company directly. Where readers face any problem about the products of NADDOD , or intend to learn more about other relevant products of the Company, they may contact us by the following ways: Website of the Company: http://www.naddod.com/...
  • Page 3 Preface Preface Introduction This file introduces NADDOD S4600 series Ethernet switches from such perspectives as product introduction, installation instruction, start after being powered on, fault maintenance. Product version The product version corresponding to this file is shown as follows. Product name...
  • Page 4 Content such as warning and prompt adopts regular script. Regular script Lucida Console The output information on the screen adopts Lucida Console form. In addition, the information input by users from the terminals among the output information on the screen adopts bold font. NADDOD Pte. Ltd.
  • Page 5: Table Of Contents

    3 First power-on and start the switch .................... 21 3.1 Build configuration environment and connect cables ..................21 3.2 Setting the terminal parameters (Windows hyperterminal) ................21 3.3 Set port parameters (SecureCRT) ........................24 3.4 Powering-on of the switch ..........................25 NADDOD Pte. Ltd.
  • Page 6 7.1 Loading failure handling ..........................32 7.2 The user password is lost ..........................32 7.3 Fault handling of power system ........................34 7.4 Fault handling of configuration system ......................34 7.5 The terminal doesn’t show fault handling .......................34 NADDOD Pte. Ltd.
  • Page 7: Product Introduction

    Product introduction NADDOD S4600 switches are high-performance 10G Ethernet switches launched by NADDOD for the intelligent campus network. This switches support high-performance IPv4 and IPv6 routes, VxLAN features and QoS strategies, and may provide medium and large-scale campus network with high-reliability, high-performance and manageable new intelligent campus network solutions.
  • Page 8: Instruction On Front Panels

    Figure 1-3 Diagram of rear panels of S4600-24X2C (1): Ground screws (2): reserved expansion slot 2 (3): reserved expansion slot 1 (4): Fan module 2 (5): Fan module 1 (6): PSU Power supplies (PS2) (7): PSU Power supplies (PS1) NADDOD Pte. Ltd.
  • Page 9: Instruction On Ports

    S4600-24X2CInstallation Instruction Manual 1 Product introduction 1.4 Instruction on ports 1.4.1 Business ports The business ports of S4600 series switches are shown in Form 1-2. Form 1-2 Business ports of S4600 series switches Product models Interface type Quantity Description S4600-24X2C...
  • Page 10 Twisted-pair of class 5 and above of cables used Maximum 100m transmission distance Standards met IEEE 802.3 Role and Used for applications and BIOS, ONIE upgrade and network service management Form 1-4 Properties of Ethernet ports used for management NADDOD Pte. Ltd.
  • Page 11: Instruction On Indicator Lights

    Because there exist differences among USB devices from different manufactures in compatibility and driving, NADDOD doesn’t ensure that the USB devices from all manufactures can be used normally on the switches. If a USB device fails to be used normally, it doesn’t belong to switch fault.
  • Page 12: Indicator Light Of Id

    Port works in 40G mode and has data receipt and sending Dark Not connected to the network cables or the port doesn’t link up Breakout Green solid This lane is in link status Green blinking This lane is in active status NADDOD Pte. Ltd.
  • Page 13 S4600-24X2CInstallation Instruction Manual 1 Product introduction Name of State Instruction indicator light Dark No link NADDOD Pte. Ltd.
  • Page 14: Installation Instruction

    2.1.2 Pre-installation check To ensure normal working environment of switch, S4600 series switches have the following requirements for workplaces: Confirm that there is space left at the air intake vent and ventilation opening of switch, so ...
  • Page 15 Form 2-1 Requirements for temperature and humidity Items S4600 series switches Temperature in working 0~45℃ environment Relative humidity in working 10%~95%...
  • Page 16: Installtion Tools

    If the optional fiber interface boards of this series switches are in working state, don’t look straight at these fiber interfaces, because the light beams of the optical fiber have energy at a very high level, which may harm the retina. 2.1.3 Installation tools Before installation, please prepare the following tools: NADDOD Pte. Ltd.
  • Page 17: Installation

    (1): The screw holes for front mounting brackets to be fixed on the rack (2): The screw holes for front mounting brackets to be fixed on the switch Front mounting brackets are only for fixing the switch and can’t be used for load-bearing. NADDOD Pte. Ltd.
  • Page 18: Install The Front Mounting Brackets To Rack With Rack Rails

    Step 4: Place the switch horizontally on the rail, push it gently into the rack along the rail, fix the other end of each front mounting bracket to the front mounting rails of rack with screws and supporting floating nuts. NADDOD Pte. Ltd.
  • Page 19: Installing The Switch To The Desktop

    4 foot pads are attached to the device, please paste them to the places near to the corners  respectively at the bottom of the switch, as shown in the following diagram: Figure 2-4 Installation diagram of foot pads NADDOD Pte. Ltd.
  • Page 20: Installation And Disassembly Of Power Module

    Step 3: Hold the handle of power supply module with one hand while pressing the fixing device, and press the top of the switch with the other hand. Step 4: Pull out the power supply module smoothly along the power supply slot. Figure 2-6 Disassembly diagram of power supply module NADDOD Pte. Ltd.
  • Page 21: Ground Wire Connection

    The ground wire connection position and grounding in the machine room shown in the diagram are only for reference, please connect based on the actual situation of devices. NADDOD Pte. Ltd.
  • Page 22: First Power-On And Start The Switch

    Please use DB-9 to RJ-45 cables provided in the box, otherwise it may be incompatible. 3.2 Setting the terminal parameters (Windows hyperterminal) Step 1. Open PC, and run terminal simulation program (e.g., hyperterminal attached to Window system) on the PC; NADDOD Pte. Ltd.
  • Page 23 115200, the data bits as 8, the odd-even check as none, the stop bits as 1, and the data flow control as none. (In other Windows NADDOD Pte. Ltd.
  • Page 24 Click the tab of “Settings” in the window of properties, enter the window of property settings (as shown in the following figure), select the terminal simulation as VT100 there, and click the button of <OK> after finishing the selection. NADDOD Pte. Ltd.
  • Page 25: Set Port Parameters (Securecrt)

    Click the button of “Quick Connect” to enter the window of quick link. Figure 3-6 Create a quick connection Select the “Serial” protocol. Figure 3-7 Serial port protocol setting Serial port number used by the PC (taking COM4 as an example). NADDOD Pte. Ltd.
  • Page 26: Powering-On Of The Switch

    3.4 Powering on the switch After the switch is powered on and started, the terminal will show the self-inspection information of the device, and after the self-inspection, the system will enter the command line prompt (e.g., switch#), etc. NADDOD Pte. Ltd.
  • Page 27 Enter the command, configure the Ethernet switch or check the operational state of Ethernet switch. May enter “?” at any time for help, and please refer to the command line manual or configuration manual for specific configuration command. NADDOD Pte. Ltd.
  • Page 28: Technical Parameters

    S4600-24X2CInstallation Instruction Manual 4 Technical parameters Technical parameters This chapter introduces the switch indicator, system indicator, single board indicator, performance indicator and other technical indicators of S4600 series switches, mainly including the following content: Switch parameters  4.1 Chassis parameters The switch parameters of S4600-24X2C are shown as below.
  • Page 29: Switch Os Loading

    Use the command setenv serverip address to set the IP address of loading server. Use the command ping to examine whether the switch is connected to the loading server. May use the command printenv to check the current environment variables of switch. NADDOD Pte. Ltd.
  • Page 30 Run the command upgrade_uboot u_boot_v1.0.bin to upgrade uBoot; here the filename is u_boot_v1.0.bin. Step 4: Run the command upgrade_uboot filename spiflash to upgrade uBoot. Here the filename is u_boot_v1.0.bin. Step 5: Run the command reset to complete the upgrade of uBoot. NADDOD Pte. Ltd.
  • Page 31: Switch Os Upgrade

    After copying the new software Image files to the designated folder of switch, you may use the command boot to set the image as the software Image to be used by the switch after the next restart. Switch(config)# boot system flash:/boot/SwitchOS-ma-v3.1.12.it.r.bin NADDOD Pte. Ltd.
  • Page 32 * 2011-05-28 10:08:38 3.1.12 SwitchOS-ma-v3.1.12.it.r.bin Among these accessed image files of software, those marked with the asterisk * ahead are the software system mirror image of operating system to be loaded after the next restart of switch. NADDOD Pte. Ltd.
  • Page 33: Maintenance And Troubleshooting

    Step 1. Restart the system, press the upward or downward key to select “ONIE” when the following interface appears, and press the Enter key to enter Step 2. Press upward or downward key again to select rescue, and press the Enter key NADDOD Pte. Ltd.
  • Page 34 17565695 8.0 GiB 8300 Switch-OS 17565696 34342911 8.0 GiB 8300 Switch-BOOT 34342912 51120127 8.0 GiB 8300 Switch-CONFIG ONIE:/ # mkdir -p /mnt/flash ONIE:/ # mount -t ext4 /dev/sda5 /mnt/flash ONIE:/ # cd /mnt/flash/ ONIE:/mnt/flash # vi startup-config.conf NADDOD Pte. Ltd.
  • Page 35: Fault Handling Of Power System

    7.5 The terminal doesn’t show fault handling After being powered on, if the configuration terminal shows no information, check as follows first: NADDOD Pte. Ltd.
  • Page 36 (e.g., hyperterminal). Please confirm the settings of parameters of terminal (e.g., hyperterminal): the Baud rate set as 115200, the data bits as 8, the odd-even check as none, the stop bits as 1, the traffic control as none, and the terminal simulation selected to be VT100. NADDOD Pte. Ltd.