2.6 2-WIRE CALL SIGNAL CONNECTIONS

2.6.1 Call Signal Connections for Audiocom,
RTS TW and Clear-Com
The call signals are superimposed on the audio signal, so
no separate call signal connections are required. However,
make sure that a call enable switch or jumper is installed
for Clear-Com applications as shown in Figures
2.6.2 Call Signal Connections for Other 2-wire
Communication System
Any other 2-wire device must be able to generate and re-
ceive a 20 kHz signal superimposed on the audio as fol-
lows:
Balanced Audio Configuration
Pin 1: No connection
Pin 2: Balanced 20 kHz + Input/Output
Pin 3: Balanced 20 kHz - Input/Output
SSA-424 Signal Specifications for balanced configuration:
SSA-424 Receive: 20 kHz ±100 Hz, 100mV p-p
SSA-424 Send: 20 kHz ±800 Hz, 1V p-p
Unbalanced Configuration 1
Pin 1: 20 kHz Common
Pin 2: 20 kHz Input/Output
Pin 3: No connection
Unbalanced Configuration 2
Pin 1: 20 kHz Common
Pin 2: No connection
Pin 3: 20 kHz Input/Output
SSA-424 Signal Specifications for unbalanced configu-
rations:
SSA-424 Receive: 20 kHz ±100 Hz, 0.3 Vrms
SSA-424 Send: 20 kHz ±200 Hz, 100 mVrms
14 User Instructions, SSA-424 Dual Digital Hybrid
5
and 6.