Wall Installation; Island Installation - Viking Designer DGRT3004BSS Install Manual

Built-in gas rangetops
Table of Contents

Advertisement

WOOD/COMPOSITE OVERLAY INSTALLATION
(Including Custom Ventilator Installation)
The bottom of any hood should be 30" (68.6 cm) min. to 36" (91.4) max. above the countertop. This would
typically result in the bottom of the hood being 66" (167.6 cm) to 72" (182.9 cm) above the floor. Refer to the
rangehood installation instructions for additional information. These dimensions provide for safe and efficient
operation of the hood.

WALL INSTALLATION

Wood/Composite Overlay
Metal Hood
Countertop

ISLAND INSTALLATION

Wood/Composite Overlay
Metal Hood
Countertop
7
Gas Connection
All gas connections must be made according to national and local codes. This gas supply (service) line must be the
same size or greater than the inlet line of the appliance. This rangetop uses an ISO7 or ISO128 inlet. The inlet
depends on the end users national and local codes.
1. Manual Shut-off Valve:
This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in
a position where it can be reached quickly in the event of an emergency. In Massachusetts: A "T" type handle
manual gas valve must be installed in the gas supply line to the appliance.
2. Pressure Regulator
a) All heavy duty cooking equipment must have a pressure regulator on the incoming service line for safe and
efficient operation, since service pressure may fluctuate with local demand. External regulators are not
required on this rangetop, because a regulator is built into each unit at the factory. Under no condition
bypass this built-in regulator.
b) Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service
company. Please provide the service person with this manual before work is started on the range. (Gas
conversions are the responsibility of the dealer or end user.)
c) This rangetop can be used with Natural or LP/Propane gas. It is shipped from the factory adjusted for use
with natural gas. To convert to LP/Propane, see conversion instructions on page 11.
d) Manifold pressure should be checked with a manometer, natural gas requires 5.0" W.C.P. and LP/Propane
requires 10.0" W.C.P. Incoming line pressure upstream from the regulator must be 1" W.C.P. higher than
the manifold pressure in order to check the regulator. The regulator used on this range can withstand a
maximum input pressure of 1/2 PSI (14.0" W.C.P.) If the line pressure is in excess of that amount, a step-
down regulator will be required.
e) The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas
supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.45 kPa).
f) The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2
psig (3.45 kPa).
3. Flexible Connections:
a) If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a
heavy-duty, agency approved flexible connector of at least 1/2" (1.3 cm) ID NPT (with suitable strain reliefs)
in compliance with ANSI Z21.41 and Z21.69 standards.
b) In Canada: CAN 1-6.10-88 metal connectors for gas appliances and CAN 1-6.9 M79 quick disconnect
device for use with gas fuel.
c) In Massachusetts: The appliance must be installed with a 36" (3-foot) long flexible gas connector.
CAUTION: Leak testing of the appliance shall be conducted according to the manufacturer's instructions. Before
placing the rangetop into operation, always check for leaks with a soapy water solution of other acceptable method.
DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS!
Electrical Connection
There is no connection necessary beyond plugging the unit into a polarized, grounded, 120 volt, 60 Hz, 15 amp circuit.
The minimum of 102 VAC is required for proper operation of gas ignition systems. Do not use GFI circuit. This circuit,
however, MUST be grounded and properly polarized. The unit is equipped with a 16-SPT2 power cord.
W A R N I N G
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong plug for your
protection against shock hazard and should be plugged directly
into a properly grounded reeptacle. Do not cut or remove the
grounding prong from this plug.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.