PROXIMITY TO SIDE CABINET INSTALLATION
1. This range may be installed directly adjacent to existing 36" (91.4 cm) high base cabinets. I I M M P P O O R R T T A A N N T T : : The top
grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertop. This may be accomplished by
raising the unit using the adjustment spindles on the legs.
2. The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical
surfaces above 36" (91.4 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the range to such
combustible surfaces above the 36" (91.4 cm) counter height.
3. Within the 6" (15.2 cm) side clearance to combustible vertical surfaces above 36" (91.4 cm) , the maximum wall
cabinet depth must be 13" (33.0 cm) and wall cabinets within this 6" (15.2 cm) side clearance must be 18" (45.7 cm)
above the 36" (91.4 cm) high countertop.
4. Wall cabinets above the range must be a minimum of 36" (91.4 cm) above the range cooking surface for the full
width of the range. This minimum height requirement does not apply if a rangehood is installed over the cooking
surface.
36"
(91.4 cm)
ELECTRICAL REQUIREMENTS
Check your local codes regarding this unit. This range requires 3 wires, 240-208/120 VAC, 60 Hz. See next section for
grounding instructions. It should be fused separately. C C A A U U T T I I O O N N : : Be sure the electrical power is off from the breaker
box to the junction box until the range is installed and ready to operate. The junction box should be located as shown
in the drawing and connected to suitable ground. Do not use GFI circuit.
36" Minimum
(91.4 cm)
13" Maximum
(33.0 cm)
0"
Adjustable Legs
30" (76.2 cm)
3/8" (.95 cm)
9
18" Minimum
0"
(45.7 cm)