SPECIFICATIONS
Electric Supply
Operating Voltage
Maximum Current
Wash Motor
Electronically commutated direct drive 3 Phase brushless DC Motor.
Motor Resistance:
Aluminium Stators
Phase 9
Pump Motor 230V AC 50Hz
Pump motor resistance:
Selni
Hanning
Water Valves
Phases 5 onwards
Water Supply
For best operating conditions your hot water should be approximately
65˚C. Your hot water should not exceed 75˚C or your cold water exceed
35˚C. Temperatures above these may cause the machine to fault or cause
damage to the machine.
If you have an uncontrolled water-heating source (e.g. a wet back or solar
heating) you should have a tempering device fitted. This will ensure the hot
water temperature remains within safe limits. For the most suitable type of
tempering device we recommend you contact a local plumber or plumbing
supply merchant.
Inlet Water Static Pressure 5psi (34.5kPa) to 150psi (1MPa).
Note: If using a header tank then the top of the header tank must be at
least 2 metres above the top of your clothes washer.
Minimum flow rate from the tap supplying the washer should be greater
than 6 litres/min (assumes ½ inch diameter pipes).
220/240V AC 50Hz
2.8 amps
Per Winding
19.5 ohms 10%
33 ohms @ 20 ° C (Thermal cut-out fitted)
93 ohms @ 20 ° C (Thermal cut-out fitted)
24 volts DC
3
Phase to Phase
39 ohms 10%
Resistance 64 ohms @ 20 ° C