Information
Intended use
(cont.)
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and results in an exclusion of liability.
Incorrect usage also occurs if the components in the
system are modified from their intended use (e.g.
through direct DHW heating in the collector).

Product information

Vitocell 300-B/-W, type EVBA-A, EVBB-A
Stainless steel DHW cylinder with internal indirect coils
for DHW heating in conjunction with solar thermal sys-
tems, floorstanding and wall mounted boilers and/or
heat pumps for dual mode operation.
Capacities:
Type EVBB-A: 300 l
Type EVBA-A: 500 l
System examples
Available system examples: See
www.viessmann-schemes.com.
Maintenance parts and spare parts
Maintenance parts and spare parts can be identified and ordered directly online.
Viessmann Partnershop
Login:
https://shop.viessmann.com/

Inspection and maintenance

DIN 1988 requires a visual inspection and (if neces-
sary) cleaning no later than 2 years after the cylinder
has been commissioned, and thereafter according to
requirements.
6
Adhere to statutory regulations, especially concerning
the hygiene of potable water.
Colours:
Vitocell 300-B, Vitosilver and Vitopearlwhite
Vitocell 300-W, Vitopearlwhite
The use of an immersion heater EHE is possible.
Suitable for systems conforming to DIN 1988,
EN 12828 and DIN 4753
Viessmann spare part app
www.viessmann.com/etapp