Wiring
2'
Communication
• 2x RJ 45 black flat cable :
rcc 02/03 / multi-units :
xtender, vt, vs, bsp, xcom
• 1x RJ 11 black flat cable for accessories :
bts 01, arm 02
EN
The device must be installed in accordance with local standards and regulations in force.
FR
L'appareil doit être installé conformément aux normes et réglementations locales en vigueur.
DE
Das Gerät muss gemäß den geltenden örtlichen Normen und Vorschriften installiert werden.
El dispositivo debe instalarse de acuerdo con las normas y regulaciones locales vigentes.
ES
8
bus termination
BAT
PV
INPUT 0-150Voc
(0-75 Voc @ 12Vdc)
12/24/48V
Earthing
• 16mm
cable
2
• The solar generator must be
class II isolated
PV connection
• 10mm
cable M5, 5Nm
2
• 25mm
cable M6, 5Nm
2
Protection device (PV side)
Switching device, max solar current
• 35A
vt 40
/ • 60A
RTC battery
remote entry
Overvoltage protection, SPD (150Vdc)
! 80V
Battery connection
• 16mm
cable M5, 5Nm
2
vt 40
• 25mm
cable M6, 5Nm
2
vt 65
Protection device (battery side)
• 50A
/ • 80A
vt 40
vt 65
vt 40
vt 65
vt 80
vt 65
/ • 75A
vt 80
In series, up to 150Voc
(75 Voc @ 12Vdc)
In parallel, see
recommended power*
Battery
vt 40
vt 65
12V
625W
1000W
24V
1250W
2000W
vt 80
48V
2500W
4000W
/ • 100A
vt 80
Lithium batteries
communication
BMS CAN
5mm
vt 80
1250W
2500W
5000W
CAN
Li
xcom CAN
9