• "1040 Keyboard and keyboard sub board" on page 66
• "1080 Keyboard bezel assembly" on page 71
Removal steps of the power button board with cable
Step
Screw (quantity)
2
M2 × 3 mm, flat-head, nylon-coated (1)
When installing:
Ensure that the connector is attached firmly.
1100 Fingerprint reader cable, bracket and board
For access, remove these FRUs in order:
• "1010 Bottom door" on page 64
• "1040 Keyboard and keyboard sub board" on page 66
• "1080 Keyboard bezel assembly" on page 71
Removal steps of the fingerprint reader cable, bracket and board
Torque
Color
Black
0.143 Nm
(1.4 kgf-cm)
.
Chapter 9
Removing or replacing a FRU
73