Operation - Yaesu FT-101E Instruction Manual

Hide thumbs Also See for FT-101E:
Table of Contents

Advertisement

OPERATION
when tuning to insure peak performance of the equip-
ment. The following paragraphs describe the procedure
for receiver and transmitter
tuning.
INITIAL
CHECK
Before
connecting
the transceiver
to a power
source,
carefully examine the unit for any visible damage. Check
that all modules
and crystals are firmly in place and
that controls and switches are operating normally. En-
sure
that voltage
specification
marked
on
rear
panel
matches
the supply voltage.
FREQUENCY
SELECTION
The
main
tuning
dial
is color
coded
with
the band
selector
switch for proper
frequency
read out. When
band selected is marked in Red, the operator reads the
Red
numbers
on
the
main
tuning
dial.
When
for
example the band selected is marked in White on trans-
ceiver front panel, the operator reads the Black numbers
on main tuning dial.
The main tuning dial is marked
in 25 KHz increments
between
each
100
KHz
segment.
This
provides
a
course frequency setting within the band. The dial skirt
surrounding
the tuning knob
is marked
in 1 KHz in-
crements
and provides
for fine settings of the trans-
ceiver operating frequency.
Following the example shown, familiarize yourself with
the relationship of main and skirt dial frequency read-
out.
00
|
RECEIVER
CALIBRATION
;
VFO
Selector ......cc
eee
INT (internal)
MOX-PTT-VOX uo.
PET
POW ER ee iiesstcecietaviea: ON (upper position )
RF GAIN wecceeeceeeeeeee Maximum
AF GAIN wccccceeeesseees As required
BAND i.e...
st thier
Desired
band
MODE vi iiaicises acecsstdecas Desired
mode
TUNING wissicctistertetes ten 100 KHz point
PRESELECTOR
|...
Desired
band segment
CLARIFIER wo.
OFF
RE CATED .c.02-eee heed OFF
CALIBRATOR wu.
100 KHz
To calibrate, set the TUNING
control to the 100 KHz
point on the dial nearest
the desired frequency. Tune
the preselector for maximum
"S" meter deflection. Tune
the transceiyer
to the 100
KHz
calibrator
signal for
zero
beat. Two
signals may
be heard near the 100
KHz
point. One of these is a signal feeding through
the
IF stages. Always
calibrate
to the stronger
of
these two signals. To calibrate, hold tuning knob firmly
at zero
beat point and
rotate
skirt vernier dial
to
zero
position.
The
skirt
vernier
dial surrounds
the
tuning
knob
and
is held
in position
by a
friction
locking device.
This dial is easily movable
by hand
but will retain its position after calibration. The trans-
ceiver must be calibrated when changing mode of opera-
tion of LSB, USB, AM
or CW,
Switch the calibrator to the 25 KHz
position and note
that the calibrator signal can
be heard
at every
25
KHz
point.
The
calibrator
switch
should
be in the
OFF
position in normal
use of the transceiver.
For bands 40-20-15-10A-10C
read Black scale on main
oY
dial. Setting shown
in the example would then be 148
KHz
plus the starting
band
edge frequency
in MHz.
For example,
on
40
meters
the frequency
would
be
7.148 MHz.
On 20 meters, 14.148 MHz, etc.
For bands 160-80-10B-10D read Red scale on main dial.
Settings shown in the example would then read 648 KHz
For example, on 80 meters the frequency would be 3.648
MHz, on 10B, 28.648 MHz, etc.